Display settings
Nio MKII 75
controller head. In that way you can easily see which display is
connected to which head.
The Display tab allows to view information about the display.
The Graphic Board tab allows to view information about the display
controller.
The Calibration tab allows to calibrate the display(s) or view the result
of the last calibration.
Display tab
•In the Display Info section, you can view the name and serial
number of the selected display.
For Nio (E-XX20) displays, you can also view:
• To select another display function, select an item from the
Display Function drop-down box.
If the selected display has been calibrated to the selected display
function in the past, the display will be set according to this
calibration. If no former calibration was found, default factory
settings are selected.
When you restart NioWatch, the last selected display function is
automatically selected.
• To adjust display luminance manually, adjust the Luminance
slider. This function is not available for MFCD/MFGD 1218
displays.
The luminance setting is saved when the system is shut down.
If the slider is positioned above the CAL mark, the luminance is in
calibrated position, as determined during the latest calibration. If
• Lifetime: Operation time including time in stand-by
• Runtime: Operation time excluding time in stand-by
• Firmware version: Version of internal display software
• Backlight Stabilization:Status of the backlight stabilization in the
display.