MDRC-2124 User manual
Copyright notice This document is copyrighted. All rights are reserved. Nor this document, nor any part of it, may be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including photocopying, taping or information storage and retrieval systems without written permission of Barco © 2010 Barco N.V. All rights reserved.
Table of Contents Table of Contents ....................................................................................... 4 Preface........................................................................................................ 5 Important notice.................................................................................... 5 Environmental information................................................................... 6 Safety Instructions.......................................................
Preface Important notice Notice Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know. Barco software products are the property of Barco. They are distributed under copyright by Barco N.V., for use only under the specific terms of a software license agreement between Barco N.V.
Environmental information Disposal Information The lamps inside the display contain mercury. Do not throw the display in the trash. Dispose of it as required by local ordinances or regulations. This equipment has required the extraction and use of natural resources for its production. It may contain hazardous substances for health and environment.
Safety Instructions General Recommendations • Read the safety and operating instructions before operating the display. • Retain safety and operating instructions for future reference. • Adhere to all warnings on the display and in the operating instructions manual. • Follow all instructions for operation and use.
Intended use This display is an AMLCD display designed for viewing medical X-ray images. This unit should not be used near patients and should be kept outside of 1.83 m perimeter and 2.29 m vertical. Power connection Power requirements: The display must be powered using a medical approved 24VDC power supply. For use only with power supply SINPRO:HPU100-108 Input:100-240V~, 47-63Hz, 1.2-0.5A The medical approved DC power supply must be powered by the AC mains voltage.
combinations – systems – shall comply with the standard IEC 60601-1-1, Safety requirements for medical electrical systems. Equipment not complying with UL/EN / IEC 60601-1 shall be kept outside the patient environment, as defined in the standard. Equipment not complying with IEC 60601 must be kept outside the patient environment, as defined in the standard as at least 1.5 meters from the patient or the patient support.
Recommendations for using your display system 1. Optimize the lifetime of your display Enabling the Display Power Management System (DPMS) of your display (in the display’s Settings menu) will optimize its diagnostic lifetime by automatically switching off the backlight when the display is not used for a specified period of time. By default, DPMS is enabled on your display, but it also needs to be activated on your workstation. To do this, go to “Power Options Properties” in the “Control Panel”.
performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels. To learn more about LCD technology and missing pixels, consult the dedicated white paper available at www.barcomedical.com. 4. Enhance user comfort Every Barco multi-head display system is color matched with the highest specification in the market. Barco recommends keeping color-matched displays together.
Cosmetics and oils on the skin are both detrimental to the screen and difficult to remove. • Allow the display to warm up to room temperature before turning it on. Avoid sudden temperature changes in the environment, as this may cause condensation, which damages the display. • Do not set up the display near strong light or heat sources. • Do not block the vents on the back of the display or install the display in a built-in enclosure.
Cleaning the display Observe the following guidelines to maintain display and LCD screen. • Use a clean, lint-free, absorbent cotton cloth to clear off any residual glue from removal of the protective film or to remove surface dust. Apply light pressure to remove the dust. • Dampen a clean cloth with a small amount of isopropyl alcohol to remove glue or dust if the screen is still not clean. Do not saturate the cloth; otherwise, alcohol may seep into the display case and collect in the enclosure.
Explanation of symbols DISPOSAL. Do not use household or municipal waste collection services for disposal of electrical and electronic equipment. EU countries require the use of separate recycling collection services. CAUTION. Read the accompanying text carefully for proper operation and maintenance of the display system.
Introduction About the product Thank you for choosing Barco. The MDRC-2124 is an LCD display with an active matrix, thin-film transistor (TFT) liquid crystal display (LCD). This product also demonstrates the following outstanding features: • DVI-I and DisplayPort signal • 24” diagonal Screen • 1920x1200 high resolution • Wide Viewing Angle Technology • 31.
Package overview User manual 16 USA Power Cord EUR Power Cord China Power Cord DisplayPort Signal Cable DVI-D Signal Cable Power Adapter
Display parts, controls and connections Front View Power LED 1. Green indicates the display is turned on. 2. Orange indicates the display is in stand-by mode.
Back View Control wheel 1. Press the control wheel for 1 sec to power off to the LCD Display. 2. Swivel the control wheel for OSD menu. DisplayPort input DVI-I input USB upstream USB downstream DC Power input Kensington Security Slot The display can be secured to your desk or any other fixed object with Kensington lock security products. Kensington lock itself is not included.
Installation Connecting the display Use only the power adapter, power cord, and the video cables shipped with this display. To setup this display, please refer to the following figure and procedures. 1. Be sure all equipment is turned off. 2. Connect the DC power cord to the power connector; plug one end of the AC power cord into the power adapter, and the other end into an electrical outlet. ( ). 3.
Note: To ensure the LCD Display will work well with your computer, please configure the display mode of your graphics card to make it less than or equal to the native resolution, and make sure the timing of the display mode is compatible with the LCD screen. We have listed the “Compatibility Modes” of this LCD screen in appendices for your reference.
Adjusting the display position Vertical height Portrait/Landscape Left to right pan Front to back tilt Remove display from stand 21
On-Screen Display menus How to use the OSD menus 1. When the display is on and the OSD in not on the screen, press the control wheel. The front illumination is switched on for about 10 seconds. 2. To display the main menu, swivel the control wheel while the illumination is on. The OSD main menu appears. Several menu items submenus. Note: Some of the menu items described in this manual may not be available on your display, depending on the selected video input. 3.
6. To change an adjustment value or setting, swivel the control wheel to select the adjustment or setting. Next, press the control wheel to go into edit mode. This is indicated by the trackbar turning dashed. Swivel the control wheel to change the value. Press the control wheel to confirm the change. For multiple choice options, the currently selected option is indicated by a “V”.
Adjustments menu Name Description Luminance Allows to manually adjust the luminance target if you’d experience the overall image is too dark or too bright. When you change this setting, the display will adjust its backlight to reach its target. Gamma Jumps to the gamma submenu (see below). White point Jumps to the white point submenu (see below). Analog Jumps to the analog submenu (see below). This submenu is only available when the DVI analog input is selected.
Name Description Gamma 1.8 Gamma 2.2 Select one of these gamma options in case the display replaces a CRT display with a gamma of 1.8 or 2.2 respectively. sRGB Select this gamma option for viewing images intended for the internet. QAWeb Select this option if you wish to use the gamma settings defined in QAWeb Agent. White point submenu Name Description Native If you select this white point option, the native panel white point behavior will not be corrected.
User submenu Name Description Red Allows to manually adjust the image red level target. Green Allows to manually adjust the image green level target. Blue Allows to manually adjust the image blue level target. Analog submenu Name Description Auto Adjust Select this setting if you wish the display to automatically adjust the geometric and level settings of the DVI analog image. Geometry Jumps to the geometry submenu (see below). Level Jumps to the level submenu (see below).
Name Description Horizontal Position Allows to manually adjust the horizontal position of the DVI analog image. Vertical Position Allows to manually adjust the vertical position of the DVI analog image. Level submenu Name Description Contrast Allows to manually adjust the image contrast target of the DVI analog image. Brightness Allows to manually adjust the image brightness target of the DVI analog image.
Name Description LED Allows to switch the power LED’s on state on/off. The LED’s orange DPMS state is not influenced by this setting. So, when the display goes into power saving mode, the LED will turn orange, even if it was switched off by this setting. OSD Settings Jumps to the OSD setting submenu (see below). Factory Reset Allows to reset the default factory settings in all OSD menus.
Information menu Name Description Display Name Indicates the display type. FW Version Indicates the current internal firmware version. Serial Nr Indicates the display serial number. Backlight Runtime Indicates the total time the display has been operating, excluding the time in stand-by. System Hours Indicates the total time the display has been operating, including the time in stand-by.
Appendix Troubleshooting If you are experiencing trouble with the LCD display, refer to the following troubleshooting. If the problem persists, please contact your local dealer or our service center. Problem: No image appears on screen. • Check that all the I/O and power connectors are correctly and well connected as described in the “Installation” section. • Make sure the pins of the connectors are not crooked or broken. Problem: Partial image or incorrectly displayed image.
Problem: Image is scrolling • Check and make sure the video signal cable (or adapter) is well connected. • Check and reconfigure the display mode of the vertical refresh rate of your graphics card to make it compatible with the LCD Display. Problem: Vague image (characters and graphics) • Use “Clock” to make an adjustment. If this problem still exists, use “Phase” to make an adjustment. Warning Signal Sometimes you may see warning messages for this LCD Display.
Product dimensions 32
Technical specifications LCD Panel Technology TFT Color LCD (E-IPS) Native resolution 1920x1200 Active screen diagonal 24.1" (611 mm) Active screen area 518 x 324 mm Pixel Pitch 0.270 x 0.
English, French, German, Spanish, Italian, OSD languages Dutch, Simplified Chinese, Traditional Chinese, Korean. Options Protective Cover Yes Touch Screen Yes Landscape/Portrait Yes Approvals EMC Safety EN 60601-1-2; FCC-B; ICES-001, VCCI, KCC, CCC, BSMI CE EN60601-1; UL 60601-1, c-UL, CCC, KCC, BSMI Mechanical characteristics Display dimensions (W x H x D) Landscape, w/o pedestal Display weight 579 x 382 x 106 mm With Stand : Without Stand : Display stand 15.
Compatibility modes Standard Resolution Vertical Refresh (Hz) Horizontal Scan (kHz) IBM VGA 640x480 60 31.5 VESA VGA 800x600 60 37.9 VESA XGA 1024x768 60 48.4 VESA XGA 1152x870 60 54.36 VESA SXGA 1280x1024 60 63.96 UXGA 1600x1200 1920x1080 1920x1200 60 60 60 75 70.2 74.
Regulatory Compliance Canada, European Union, United States This display has been tested and found to comply with IEC/UL/EN 60601-1 and IEC 60601-1-2 standards, and is certified to meet medical standard UL 60601-1 and CAN/CSA C22.2 No 601.1(C US Mark) which are related to electrical shock, fire and mechanical hazards only as shown on right UL mark on this page.
The display was classified as required by the MDD according to Annex IX of the directive and the medical device (MEDDEV) guidance available at the time of classification. Because the display uses electrical energy and has no direct patient connections and—by itself—no medical utility, the display is classified according to Rule 12 as an MDD Class I device, component, or accessory.
EU EMC Directive 89/336/EEC EU Electromagnetic Compatibility Directive EN 60601-1-2 (2001) Collateral standard electromagnetic Medical Electrical Equipment compatibility requirements EN 55011 (Class B) Limits and methods of measurements for radio interference characteristics of industrial, scientific, and medical equipment IEC 61000-3-2 Harmonic emissions IEC 61000-3-3 Voltage fluctuations/flicker emissions IEC 61000-4-2 Electrostatic discharge requirements for industrial process measurement and
IEC 61000-4-6 Conducted immunity IEC 61000-4-8 Magnetic field immunity Conformance to the Medical Device Directive 93/42/EEC EN 60601-1 Medical Part 1 General requirements for safety Electrical Equipment. U.S. FCC Compliance Statement This device complies with Part 15 of the FCC Rules.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technical for help. CAUTION: Changes or modifications to this equipment not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
BARCO MID GENERAL WARRANTY TERMS AND CONDITIONS Applicable from Jan 1st 2008 ARTICLE 1: PRODUCT WARRANTY Barco nv, Medical Imaging Division warrants that the equipment will be free of defects in workmanship or material for the warranty period or the specific period of a warranty extension program.
1.3 The Customer shall return, freight prepaid, the defective equipment or subassemblies in its original packaging with the assigned RMA number for repair to the Barco nv, MID Customer support centre (or an authorised service centre). 1.4 Replacement parts used shall be new or equivalent to new parts for the revision level of the equipment. A replacement LCD panel will be new or similar run time.
mal functioning of the hardware covered under this Agreement. 2.4 Normal wear and tear, use under circumstances exceeding specifications, such as use in dusty environment or under excessive temperature conditions, abuse, unauthorised repair or alternation, lack of proper configuration or maintenance, damaged or modified or removed serial number, cosmetic refurbishment. 2.
iv. difference in color temperature as a result of not using all displays of a multi-head configuration at the same rate. v. LCD luminance uniformity that is in within the product specifications or luminance uniformity performance that is inherent to LCD technology. Barco nv, MID does not warrant a minimum life time nor a performance of any of the consumables. 2.6 Replacement of moveable parts such as power cords, remote controls, … 2.
version of the software. (c) The repair or replacement under the Warranties covers the cost of material and labor. ARTICLE 5: DISCLAIMER OF WARRANTIES BARCO NV, MID DISCLAIMS ALL WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
B410640-01 November 2010 Barco nv Medical Imaging President Kennedypark 35 B-8500 Kortrijk, Belgium www.barco.