10.1 Floor S pace and Maintenance Area
Sufficient floor space and maintenance area must be available when installing O
VERVIEW MDR50-
DL
Floor Space
The floor space must have a sufficient load carrying capacity and be sufficiently flat (according to
DIN 18202). It must not sag by more than 1 millimeter under the load of the O
VERVIEW MDR50-
DL. A cement, wood or false floor is permissible.
The load of the O
VERVIEW MDR50-DL is transmitted to the floor via adjustable feet.
No installations (venting ducts, sockets etc.) must be present in the floor in the area of the feet or
of the lower anchoring devices. An area of at least 15 centimeters must be kept free around each
foot. The loading capacity in the area of the feet must be sufficient. Height differences up to
±5 millimeters can be compensated using the adjustable feet.
Figure 10-1
Position of the feet and anchoring brackets of O
VERVIEW MDR50-DL
(All dimensions measured in millimeters!)