Installation manual
8. Final Adjustment and Configuration
OverView D 50" – DOC-3303-5 – installation manual – Revision 11 – November 2006
________________________________
________________________________________________________________
_________________________________________________________
__________________________________________________
_________________________
8-21
Figure 8-26
message at dimmer range limit
Please note: this error message does not indicate a dimmer failure!
This message indicates that the dimmer cannot achieve the desired value but operates
at his limits (100%, or 50% respectively).
In this operation mode, the commands of the Brightness menu are available:
Figure 8-27
Brightness menu commands are available
8.5.4.5 Optical Dimmer
OverView D uses a dimmer wheel with a variable slit. The slit defines the light aperture of the light pipe entry.
Figure 8-28
Dimmer Wheel, variable slit
The amount of light emitted into the projection unit depends on the position (i.e. slit width) of the dimmer
wheel.