Installation manual
6. Installation of Projection System
6.9 Running the fans
Before taking the system into operation it must be ensured that the fans and the hoses are dust free. Therefore
remove again the hoses from the illumination unit and the projection unit and start the fan.
Run the system in standby! Do not switch on the lamps!
The fans should run for about 5 minutes before continuing. Then re-attach the hoses.
Now you can start with the adjustment procedure
6.10 Settings of the Multi Input Module and the controller (SXGA emulation)
6.10.1 Multi Input Module
The Multi Input Module has to be set to the SXGA resolution. In the main menu, select Geometry|Display|Pixel.
Adjust the value from 1400 to 1280.
Subsequently go to Geeometry|Display|Line and adjust the value from 1050 to 1024.
Select Geometry|Advanced|Original.
Set both, the X-position and the Y position, to zero
6.10.2 Controller
The Multi Input Module processes the incoming SXGA signal into an SXGA+Signal with black borders.By zooming
out you can remove the black border.– With TransForm A controller,,take care to switch the rotary switch on the
UGX graphics card to position 8.For Hydra controller,change the resolution in I-studio
(module->setup module ->screen)to “DLP SXGA native size ”and reboot the Hydra.