The following table lists the encoder specific values. They are valid with STREAMING VIDEO CARD with firmware 6.0.
The values for TCP and Video PID must be entered not into the Setup encoders dialog but into the Setup
Streams dialog, please refer to the next section. The compression algorithm must be entered in the Setup
module dialog on the boards tab; please refer to section 5.3.4 Setup module.
Encoder
manufacturer – type
compression
algorithm
IP
protocol
Skip at
start
Skip at
end
Stream
type
TCP Video
PID
AXIS – mjpeg TCP 0 0 auto ON 0
Use port 80 for TCP and indicate the encoder IP address; signaling method is
http; signaling is supported.
206 Startstring example: Axis241Q://GET /axis-cgi/mjpg/
ª video.cgi HTTP/1.0\n\n
206M Startstring example: Axis241Q://GET /axis-cgi/mjpg/
ª video.cgi HTTP/1.0\n\n
Resolutions with 1280 horizontal pixels are not supported.
207 / 207W / 210 /
210A / 211 / 211A /
213 PTZ / 214 PTZ /
216FD / 225FD / 231D /
231D+ / 232D / 232D+ /
241S / 241SA / 242S IV
Startstring example: Axis241Q://GET /axis-cgi/mjpg/
ª video.cgi HTTP/1.0\n\n
221 Startstring example: Axis241Q://GET /axis-cgi/mjpg/
ª video.cgi HTTP/1.0\n\n
Up to 30 frames/sec
240Q Startstring example: Axis241Q://GET /axis-cgi/mjpg/
ª video.cgi?camera=1 HTTP/1.0\n\n
241Q / 241QA Startstring example: Axis241Q://GET /axis-cgi/mjpg/
ª video.cgi?camera=1 HTTP/1.0\n\n
A maximum use of 4 4CIF streams with a maximum quality of 75% (or at
least 25% compression) is recommended.
Barco – TransForm SCN scn UDP 0 0 auto OFF 0
h263 RTP 0 0 auto ON 0 BOSCH – NWC-0455 Dinion /
NWC-0455 DinionXF /
VideoJet8008 / VIP X1 /
VIP X1600 / VIP X2
No on-board RCP+ support; I-frame distance may not be 0.
Startstring example: VIP X
h263 RTP 0 0 auto OFF 0 BOSCH – Videojet 10 / Video-
jet 1000 / Videojet Xpro /
VIP 10 / VIP 1000
No on-board RCP+ support; I-frame distance may not be 0.
mpeg2 RTP 4 0 auto OFF 0 BOSCH – Videojet 1000 / Video-
jet 8000 / Videojet Xpro /
VIP 1000
No on-board RCP+ support.
Cieffe – NETTUNO mpeg4 UDP 0 0 auto OFF 0
Coretec – VCX-2400-E mpeg2 UDP 0 0 auto OFF 0
Cornet –
iVDO Streamer 2/4 Encoder
mpeg2 UDP 0 0 auto OFF 0
Cornet –
iVDO Streamer 2/4 Encoder
mpeg4 RTP 0 0 auto OFF 0
DVTeL – 7601e mpeg4 RTP 0 0 auto ON 0
Use port 3000 for TCP,
Startstring example: SmartSight