User`s manual

5. Menu and toolbar
Barco – iStudio – R5976569 – user's manual – revision 09 – March-2007
____________________________________________________________________________________
5-40
Startup tab
On the Startup tab, the layout of the module during H
YDRA startup can be chosen. As default a black screen with
the IP address of the H
YDRA and the version of iSTUDIO will be displayed. Alternatively to that, the layout that was
displayed at the shutdown can be displayed or a layout from the layouts list can be chosen.
Alarm tab
In order to notify of a general H
YDRA alarm one tally of a video source can be selected. Therefore the Enable tally
on alarm checkbox must be selected and a video source must be chosen from the source list. With the second
list one of the tallies of the source can be specified. By this it is for example possible to control an external
buzzer that is connected to the hardware output of the specified source, if an alarm occurs.
Only tallies that are configured as hardware output tallies or as software tallies can be used and
are itemized; please refer also to section
5.3.7 Setup source (Tally tab).
One tally may at one time only be used for one alarm method:
Enable tally on alarm is selected on the Alarm tab of the Module properties dialog (Setting
of this tab),
tally is enabled on the Alarm tab of the Source properties dialog, please refer to section
5.3.7
Setup source,
Set Tally on alarm on the Tally tab of the Source properties dialog.
If one tally is already enabled in one of the other mentioned dialogs, it will not be available in the
tally list of this dialog.
When selecting a tally of a Quad SDI video input card or a Quad analog video card there are also
three tallies offered even though there are only two tallies available per source. Therefore tally
three may not be selected! For a source of the Streaming video card, no tally may be selected!
On the NTP Alarm tab an alarm can be activated in case of the loss of NTP synchronization, please refer also to
section
7.1.2 Synchronization errors. To configure an NTP alarm is only expedient, if the time setup of the respective
H
YDRA module is configured for NTP (not NTP Date) or for LTC/VITC synchronization (LTC/VITC only in wall mode),
otherwise the alarm will always be active, please refer to section
5.2.7 Time setup.
To enable an alarm click the Enabled checkbox. With the Delay (seconds) box the seconds are indicated be-
tween the alarm is detected and it is displayed. With the Clear checkbox it can be selected whether alarms are
automatically cleared within a Delay of seconds or not.
With the four checkboxes Logging, Show in alarm list, Ring buzzer, Send SNMP it can be selected on which
interfaces an alarm shall be reported.
If Ring buzzer is enabled, on the wall alarms area the buzzer toggle button must also be activated to be able to
ring the buzzer, please see section
5.2.2 Wall alarms area.
If an SNMP trap shall be sent, in the setup module dialog, SNMP must be configured, please see section
5.3.4
Setup module (Network tab). The Use interval checkbox enables to report errors within user defined time intervals.
These intervals can be created and edited with the Define intervals dialog. You find a description of this dialog
in section
5.3.7 Setup source (Alarms tab).