5.2.5 Wall Control
The following commands are applied to all HYDRA devices of the wall. Please refer to section 5.3.2 Module control
for an instruction how to control a single H
YDRA.
Halt wall
With the Halt wall command all H
YDRAS belonging to the wall can be halted. A warning dialog appears. After
confirming this dialog the shutdown screen is displayed while halting. When halted the display is just black and
the H
YDRAS can be switched off, please refer to the HYDRA user’s manual.
Reboot wall
The Reboot wall command halts all H
YDRA devices of the wall and reboots them. This includes a reset of the
software and all hardware components. The warning dialog must be confirmed, before the wall is rebooted.
The command must be applied after changes of Name or Wallname within the dialog
5.3.4 Setup module to make
them become effective. If changes have been made for one module it is sufficient to apply the command
Reboot module to the respective H
YDRA module instead.
Be aware that the connection between the GUI and the H
YDRA modules is interrupted while re-
booting. You will have to reconnect to the H
YDRA when the wall has rebooted!
Reset wall
The Reset wall command resets the software and all hardware components of the H
YDRA devices of the wall,
except the single board computer. The warning dialog must be confirmed, before the wall is reset. If changes
have been made for only one module, it is sufficient to apply the command Reset module to the respective
H
YDRA module instead.
Reset Software (Wall)
The Reset Software (Wall) command resets the software of the H
YDRA devices of the wall. During the software
reset, each module keeps on displaying its part on the display wall.
The command must be applied after changes to make them become effective. The following changes are con-
cerned:
• changed content of the folders logo and anim, please refer to section
8.1 Data structure and data access (reset
software is required to update the file lists, e.g. when selecting the logo of a logo object,
• for some NTP synchronization operations, please see section
5.2.7 Time setup.
If changes have been made for one module it is sufficient to apply the command Reset software (Module) to
the respective H
YDRA module instead.