User`s manual

11. Appendix A - Hydra Open Protocol
Barco – iStudio – R5976569 – user's manual – revision 09 – March-2007
__________________________________________________________________________________
11-46
Incoming
event
<XML>
<PACKET MODULE="HYDRA" VERSION="1.0">
<EVENT ID="alarmchanged" CHANGE="active"> active, solved, cleared
<MODULE ID="module3">
<SOURCE ID="17">
<ALARM ID="videoloss">
<ACTIVE>1</ACTIVE>
<CLEARED>0</CLEARED>
<STARTED>09:19:32</STARTED>
<STARTEDDATE>29/9/2005</STARTEDDATE>
</ALARM>
</SOURCE>
<SOURCE ID="-1">
<ALARM ID="ntpsynchrolost">
<ACTIVE>1</ACTIVE>
<CLEARED>0</CLEARED>
<STARTED>10:58:15</STARTED>
<STOPPED>10:58:15</STOPPED>
<STARTEDDATE>29/9/2005</STARTEDDATE>
<STOPPEDDATE>29/9/2005</STOPPEDDATE>
<FLAGS>1</FLAGS>
</ALARM>
</SOURCE>
</MODULE>
</EVENT>
<EVENT ID="alarmchanged" CHANGE="cleared">
<MODULE ID="module1">
<SOURCE ID="7">
<ALARM ID="audioloss">
<ACTIVE>0</ACTIVE>
<CLEARED>1</CLEARED>
<STARTED>09:19:33</STARTED>
<STOPPED>09:19:34</STOPPED>
<STARTEDDATE>29/9/2005</STARTEDDATE>
<STOPPEDDATE>29/9/2005</STOPPEDDATE>
</ALARM>
</SOURCE>
</MODULE>
</EVENT>
</PACKET>
</XML>
See also getlistalarms, getmodulestate, getsourcealarm
File changed
This event reports that a file has been saved or deleted on the wall.
Enable /
disable
<XML>
<PACKET MODULE="HYDRA" VERSION="1.0">
<EVENT ID="filechanged" SERIAL="example">
<ENABLE></ENABLE> enable file events
<DISABLE></DISABLE> disable file events
</EVENT>
</PACKET>
</XML>
Incoming
event
<XML>
<PACKET MODULE="HYDRA" VERSION="1.0">
<EVENT ID="filechanged"></EVENT>
</PACKET>
</XML>
See also deletefile, getlistfiles, savefile