User`s manual
11. Appendix A - Hydra Open Protocol
Barco – iStudio – R5976569 – user's manual – revision 09 – March-2007
__________________________________________________________________________________
11-26
Clear log file
Clear the log file of a H
YDRA module.
Send
<COMMAND ID="clearlogfile" SERIAL="example">
<MODULE ID="module1"></MODULE>
<MODULE ID="module2"></MODULE>
</COMMAND>
For each log file specify: module name
Receive
<COMMANDRESULT SERIAL="example" ERROR="0">
</COMMANDRESULT>
See also getlogfile
Get module time
Get the current time and date of a H
YDRA module. This is the internal time the HYDRA was set to. Timezone as-
signments are not considered.
Send
<COMMAND ID="getmoduletime" SERIAL="example">
<MODULE ID="module1"></MODULE>
</COMMAND>
For each time and date: specify module
Receive
<COMMANDRESULT SERIAL="example" ERROR="0">
<MODULE ID="module1">
<HOUR>15</HOUR>
<MINUTE>12</MINUTE>
<SECOND>9</SECOND>
<DAY>20</DAY>
<MONTH>6</MONTH>
<YEAR>2001</YEAR>
</MODULE>
</COMMANDRESULT>
See also setmoduletime, setwalltime
Set module time
Set date and time for a H
YDRA module.
Send
<COMMAND ID="setmoduletime" SERIAL="example">
<MODULE ID="module1">
<TIME>
<HOUR>15</HOUR>
<MINUTE>12</MINUTE>
<SECOND>9</SECOND>
<DAY>20</DAY>
<MONTH>6</MONTH>
<YEAR>2001</YEAR>
</TIME>
</MODULE>
</COMMAND>
For each module specify: module name, new time and date
Receive
<COMMANDRESULT SERIAL="example" ERROR="0">
</COMMANDRESULT>
See also getmoduletime, setwalltime