User`s manual

11. Appendix A - Hydra Open Protocol
Barco – iStudio – R5976569 – user's manual – revision 09 – March-2007
__________________________________________________________________________________
11-15
tton true | false switch teletext decoding on
ttvisible true | false show teletext characters on screen
ttpage a number from 100 to 899 the subtitle page
ttusetruetype true | false use a truetype font to display teletext
tttruetypefont-
name
the name of the truetype font (if ttusetruetype is true)
vitcvisible true | false should the VITC counter be visible or not
wsson true | false switch wide screen signaling on/off
wssindicator true | false show/hide the WSS indicator
wssmode
none | WSS | WSS/AFD |
VLI/AFD | ETSI
the WSS mode
wsscolor color name from rgb.cfg file background color behind the video when WSS is used
wssdefault none | 4/3 | 16/9 default aspect ratio when no WSS is found
wssarc true | false let the video size follow the WSS signal
afdon true | false switch AFD on or off
afdlines true | false show/hide the AFD lines
afdindicator true | false show the AFD indicator
afdshowerror true | false show deviation from standard
etsion true | false switch ETSI on or off
etsilines true | false show/hide ETSI lines
etsiindicator true | false show/hide ETSI indicator
audiodirection V | H direction of audiobars horizontal or vertical
Audio
entry value meaning
audiosource 0 | 1 | 2 | … the source number
backcolor color name from rgb.cfg file the background color
barwidth a number between 2 and 30 the pixelwidth of the audiobars
audioscale
BBC PPM | DIN | Nordic |
VU | Ext VU | AES/EBU
the scale mode of the audio bars
audioplain true | false show plain audiobars (without scales)
audiodirection V | H direction of audiobars vertical or horizontal
erroron true | false show errors by blinking the border
errorcolor color name from rgb.cfg file The blinking color of the border in case of an error.
clearcolor color name from rgb.cfg file
The blinking color of the border, if an alarm is solved but
not yet cleared.
errorname true | false show the errorname in the object
Clock
entry value meaning
digital true | false digital clock or not
morph true | false morphing clock or not, if digital is true
twelve true | false 12 hours or 24 hours, if digital is true
offseth a value between -12 to 12 the offset in hours
timezoneenabled true | false a distinct timezone is used