Slot[<nr>]: DSP load failed
The software was not able to load the DSP on the audio board in the
specified slot:
• Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: Slot[<nr>]: Unknown
ª board type <BoardType>
The software detected in the specified slot a board with the specified
boardtype, that is not known by the software:
• Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
• Check if the iStudio CD-ROM is up-to-date
No overlay input found The software detected no overlay input card:
• If there is no overlay input card, a board must be insterted into
slot0; contact the Barco support.
• If there is an overlay input card, try <reset module>. If the error
keeps occurring, the board must be replaced; contact the Barco sup-
port.
No source inputs found The software detected no video or RGB input card:
• If there are no video or RGB input cards, those cards must be
inserted into the slots between the overlay input card and the
output card; contact the Barco support.
• If there are video or RGB input cards: Retry <reset module>. When
the error keeps occurring, the boards must be replaced; contact the
Barco support.
No Output found The software detected no output board:
• when there is no output board an output board must be inserted in
the first slot after the last source input board; contact the Barco sup-
port.
• if there is an output board: Retry <reset module>. When the error
keeps occurring, the board must be replaced; contact the Barco sup-
port.
Slot[<nr>]: (output) board lost The software lost connection to the output board:
• Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
ovly: <filename> not found
The software could not find the specified file to load to the overlay input
card:
• Contact the Barco support
ovly: Failed loading DVI Hotplug
ª detect EEPROM
The software could not load the information into the EEPROM for auto-
matic DDC-data detection on the overlay input card:
• Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
ovly: Failed loading eMaintenance
ª EEPROM
The software could not load the information into the EEPROM for eMain-
tenance on the overlay input card:
• Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: Ovly Failed progamming
ª key
Writing to SDRAMs on overlay input card had timed out:
• Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.