User`s manual

7. Error messages
Barco – iStudio – R5976569 – user's manual – revision 09 – March-2007
_____________________________________________________________________________________
7-5
Corrupt gmZX1 configuration
The software did not configure the scaler on the analog or SDI video
input card:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: Overlay input only
ª allowed in first slot
The position of the overlay input card is fixed to slot0:
The position of the overlay input card must be changed to slot0.
Please refer to the HYDRA user’s manual and contact the Barco sup-
port.
Slot[<nr>]: Found already an
ª Overlay input in an previous
ª slot
There is only one overlay input card allowed in one HYDRA:
The overlay input card, which is not inserted in slot0, must be re-
moved. Please refer to the HYDRA user’s manual and contact the
Barco support.
Slot[<nr>]: Altera load failed
The software did not manage to load the altera on the board in the
specified slot:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: Hardware initialisation
ª failed
The software did not manage to initialize the hardware on the board in
the specified slot.
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: GAP between boards not
ª allowed
The software did not detect a board in the slot <slotnr – 1>:
A board must be inserted in slot <slotnr – 1>.
If there is a board in the slot then retry <reset module>. If the
error still occurs then the board that is not detected must be re-
placed; contact the Barco support.
Slot[<nr>]: No Overlay input found
ª in a previous slot
There was no overlay input card in the slot <slotnr – 1>:
When there is no overlay input card an overlay input card must be
inserted in slot0.
If there is an overlay input card: retry <reset module>. If the error
still occurs then the overlay board must be replaced; contact the
Barco support.
Source input not allowed after an
ª output
The software detected one or more input cards in a slot after the output
card:
The output card must always be inserted after the last input card
Slot[<nr>], Channel[<nr>]:
ª Hardware initialisation failed
The software did not manage to initialize the hardware on the specified
channel of the board in the specified slot:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: GAP between outputs
ª not allowed
The software detected an empty slot between two outputs:
If there is an empty slot: an output card must be inserted in the
empty slot; contact the Barco support.
If there is an output card in the specified slot: Retry <reset
module>. When the error keeps occurring, the board must be re-
placed; contact the Barco support.
Slot[<nr>]: Xilinx load failed
The software was not able to load the Xilinx device on the audio board
in the specified slot:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.