User`s manual

7. Error messages
Barco – iStudio – R5976569 – user's manual – revision 09 – March-2007
_____________________________________________________________________________________
7-4
7.2 Device related errors
Device related errors are shown in the module status list; please refer to section 5.3.3 Module status.
7.2.1 Hard- and software errors
Hardware or software errors of HYDRA and a first analysis for these errors are given in the table below:
Error message Analysis
Slot[<nr>]: <boardnr> <filename>
ª not found
A specific file to be loaded in an altera device on the specified board
was not found:
Contact the Barco support
Slot[<nr>]: Altera load: <boardnr>
ª <filename> not found
A specific file to be loaded in an altera device on the specified board
was not found:
Contact the Barco support
Slot[<nr>]: Altera load: <boardnr>
ª <filename> is empty
The specific file to be loaded in an altera device on the specified board
is empty:
Contact the Barco support
Slot[<nr>]: Altera load: ConfDone
ª does not answer
The altera device(s) of the board in the specified slot do not confirm
that the configuration was successful:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: Altera load: Cannot load
ª databytes
The software could not load data to the altera device(s) on the board in
the specified slot:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: Altera load: Status does
ª not answer
The altera device(s) of the board in the specified slot does not confirm
its status to the software:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
am56InitAESBoard: TimeOut(<x>) The software could not initialize the audio board in the specified time:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: Xilinx load: <slotnr>
ª <filename> not found
The specific file to load into the Xilinx device on the audio board in the
specified slot was not found:
Contact the Barco support
am56InitXilinx: TimeOut(<x>)
The software could not initialize the Xilinx device on the audio board in
the specified time:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
am56InitDSP: TimeOut(<x>)
The software could not initialize the DSP on the audio board in the
specified time:
Retry <reset module>. When the error keeps occurring, the board
must be replaced; contact the Barco support.
Slot[<nr>]: DSP load: <slotnr>
ª <filename> not found
A specific file to be loaded in a DSP device on the audio board in the
specified slot was not found:
Contact the Barco support
Slot[<nr>]: DSP load: <slotnr>
ª <filename> is empty
The specific file to be loaded in the DSP on the audio board in the speci-
fied slot is empty:
Contact the Barco support