B4102010/Rev. 00 October 2002 BarcoView Theodoor Sevenslaan 106 8500 Kortrijk, Belgium Phone: +32(0)56 23 32 44 Fax: +32(0)56 23 33 74 E-mail: sales.medical@barco.com http://www.barcoview.com BarcoView Inc 3059 Premiere Parkway IMAGETILE® Softcopy Digital Lightbox Duluth, Georgia, 30097,USA Phone: +1 678 475 8000 Fax: +1 678 475 8100 E-mail: sales.medical@barco.com http://www.barcoview.com BarcoView LTD 16F-1, Cheng Loong Plaza 33, Min Sheng Road Section 1, Pan Chiao, Taipei Hsien, Taiwan, R.O.C.
SAFETY INSTRUCTIONS Power connection • Read the safety and operating instructions before operating the apparatus. • Retain safety and operating instructions for future reference. • Adhere to all warnings on the apparatus and in the operating instructions manual. • Follow all instructions for operation and use. •This apparatus conforms to: UL 2601-1, c-UL CAN/CSA-C22.2 No. 601.
(This page intentionally left blank.
CONTENTS Overview .............................................................................................................................. 8 Introduction ......................................................................................................................... 10 ImageTile installation overview ..................................................................................... 10 ImageTile features .......................................................................................
Installing the Driver Using the Windows NT 4.0 Display Properties Control Panel 41 Setting the Resolution of Your ImageTile Display Panel ......................................... 42 Installing the BarcoMed 3MP2FH Windows 2000 Display Driver ................................ 43 Installing the Driver Using the BarcoMed Driver Installation Wizard ...................... 43 Setting the Resolution of Your ImageTile Display Panel with DualView Disabled ..
End Work Day .......................................................................................................... 92 Screen Saver During Work Day ............................................................................... 92 Available Savers ....................................................................................................... 93 Settings ....................................................................................................................
OVERVIEW
Overview (This page intentionally left blank.
Overview INTRODUCTION ImageTile installation overview To install the ImageTile system completely, you have to follow these steps: 1 Install the imaging board(s) in the PC 2 Install the ImageTile and connect the signals from the PC 3 Install the BarcoMed driver software 4 Setup Sentinel 5 Install the MediCal software 6 Use MediCal ImageTile features ImageTile For enterprise-wide image distribution in a softcopy reading environment, Barco has designed IMAGETILE®. This digital lightbox system, combining 20.
Overview I-Guard I-GUARD® is Barco’s patent-pending, built-in calibration device, continuously maintaining image quality. With I-GUARD®, QA checks no longer need to disturb normal radiology activities, as they can be performed while applications are running. I-GUARD® allows radiologists or QA administrators to calibrate their viewing stations or adjust the panel’s curve to DICOM standards without administrator intervention.
Overview CONTROLS AND CONNECTORS (1) (2) (3) (2) (1) Power LED - The LED is off when the display is plugged out from power. - The LED is green when the display is on. - The LED is red when the display is in Stand-by power-saving mode. (2) USB-downstream connector (3) Soft switch: Press the switch to switch on the panel. Press the switch again to switch the panel in stand-by.
Overview (4) (2) (4) (5) (2) (6) (7) (4) (2) (4) (2) (2) USB-downstream connector (1 per head) (4) DVI (video and data) input (1 per head) (5) USB-upstream connector The USB interface can be used as USB hub. If you connect the USB-upstream connector to the computer, you can use the USBdownstream connectors to plug in USB compatible devices.
IMAGING BOARD INSTALLATION
Imaging board installation (This page intentionally left blank.
Imaging board installation 3MP2FH PRODUCT OVERVIEW The BarcoMed 3MP2FH Graphics Controller delivers a quality 2048x1536 pixel image with 1024 simultaneous shades of gray for medical imaging applications. Features of the BarcoMed 3MP2FH • Dual Head Configuration • 2048 x1536 resolution at 60 Hz • 10 bit performance on LCD • 32MB Video Memory • Portrait or Landscape Mode • 1024 Simultaneous shades of gray • Hardware cursor • Single slot PCI card • Control Panel supports the English ( U.S.
Imaging board installation System Configuration Guidelines Because of the low power consumption and low heat generation of the 3MP2FH, multiple boards may be installed in adjacent PCI slots or adjacent to other PCI boards. Additionally there should be no need to modify either the PC’s power supply and/or cooling system.
Imaging board installation PLANNING YOUR 3MP2FH INSTALLATION Important installation considerations Preparations before installation 1 Make certain all equipment is switched off. 2 In case you use a PCI expansion chassis, please install it following the guidelines in its User’s Guide. 3 Familiarize yourself with the 3MP2FH Imaging Board and the cables used to connect it to the display panel. 4 Read through this guide from beginning to end.
Imaging board installation (This page intentionally left blank.
Imaging board installation HARDWARE INSTALLATION Notice: Wear a protective ESD strap during installation or handling of the board. Electrostatic charges can damage the board. Familiarizing Yourself With the 3MP2FH Prior to installing your 3MP2FH board(s) in your PC please take a few minutes to familiarize yourself with both the board and the PCI slots in your computer. Figure 1: The 3MP2FH Switch Locations There are four switches located at SW1 on the 3MP2FH.
Imaging board installation Sw itch Function VGA EN Enables VGA on the Pri mary Head (default i s ON). BIOS EN Allows the System BIOS to read the VID EO BIOS (default i s ON). NORMAL C ontrols Board State (default i s ON). INT C LK Internal C lock (default i s ON). The swi tches are i n the ON posi ti on when the whi te sli der swi tch i s posi ti oned towards the top of the board.
Imaging board installation Figure 2: PCI and RAID Controller Slots Installing the BarcoMed 3MP2FH Graphics Controller Install the 3MP2FH into your computer following these steps: 1. Turn off the power to your computer and disconnect the power cord. 2. Remove the chassis cover according to the manufacturer’s instructions. Be sure to observe safety warnings. 3.
Imaging board installation Running Multiple BarcoMed 3MP2FH Boards in a Single Host The physical order of the displays may vary when you are running multiple BarcoMed 3MP2FH boards. This is due to the PC’s PCI bus control in the system BIOS, and not the BarcoMed board. It may become necessary, depending on how your PC’s BIOS configures the PCI bus, to switch your DVI display connections to achieve a linear desktop configuration. Figure 3: The Video Outputs.
IMAGETILE DISPLAY PANEL INSTALLATION
ImageTile installation (This page intentionally left blank.
ImageTile installation PRECAUTIONS • Keep your original packaging. It is designed for this product and is the ideal protection during transport. • Avoid reflections in the flat panel to reduce eye strain. • The wall to which you mount the panel must be strong, stable and solid enough. • Keep the display away from heat sources and provide enough ventilation. • Make sure the computer is switched off before connecting the signals.
ImageTile installation Bracket mounting instructions - The wall must be a solid concrete wall. - The wall must be strong enough to bear a weight of at least 4 times the panel you are installing. Please refer to the Technical specifications chapter to know the weight of the panels. - Screws must be size M8, 8 cm long - The screws must be matched to be used in concrete. - Use 4 screws: One for each suspension hole. Do not leave any of the suspension holes open.
ImageTile installation Bracket lock Keystone plate Inclined sliders Tilting the panel You can tilt the panel in two directions: forward (+10%) and back (-5%) To tilt the panel forward (+10%) To tilt the panel, proceed as follows: 1 Loosen the bolts (A) 2 Loosen the bolts (B) a little bit 3 Loosen the bolts (C) a little bit 4 Pull the top of the ImageTile panel forward 5 Fix the bolts (A, B, C) again System manual ImageTile 28
ImageTile installation 10° -5° A B A B C C To tilt the panel backward (-5%) To tilt the panel, proceed as follows: 1 Loosen the bolts a little bit (A) 2 Loosen the bolts (C) 3 Loosen the bolts (D) 4 Pull the bottom of the ImageTile panel forward 5 Fix the bolts (A, C, D) again 10° -5° A A C D C D System manual ImageTile 29
ImageTile installation CONNECTING THE SIGNALS To connect the signals: 1 Be sure the imaging board(s) are installed according to the instructions from the "Imaging board installation" chapter in this manual. For a dual-head panel, 1 board must be installed. For a quad-head panel, 2 boards must be installed. 2 Connect the outputs of the imaging board(s) to the DVI connectors (4) on the panel. For each board, the leftmost head must be connected to the Vid1 output (see illustration).
ImageTile installation STARTING UP Proceed as follows: 1 Switch on the computer. 2 If the panel is in stand-by, press the soft switch (3) once. The power LED (1) is green in the on-state and red in stand-by. 3 Now install the BarcoMed imaging board driver (see next section). Note: The image resolution you have to select in the imaging board driver is 1536 x 2048.
ImageTile installation (This page intentionally left blank.
BARCOMED SOFTWARE DRIVER INSTALLATION System manual ImageTile 33
BarcoMed software driver installation (This page intentionally left blank.
BarcoMed software driver installation SOFTWARE INSTALLATION Overview The BarcoMed 3MP2FH Software Installation section has been divided into three sections, one for each of the three supported versions of the Windows operating system. They are: Windows NT 4.0, Windows 2000 and Windows XP. In addition to the device drivers for your BarcoMed imaging boards, your BarcoMed Software CD also includes several additional tools.
BarcoMed software driver installation Installing the BarcoMed Imaging Board Windows NT 4.0 Display Driver Installing the Driver Using the BarcoMed Driver Installation Wizard SPECIAL NOTE: Prior to installing the BarcoMed Display Drivers you MUST install the BarcoMed Imaging Board(s), connect the ImageTile display panel(s) to the card(s) and turn the ImageTile display on.
BarcoMed software driver installation Figure 5 3. The Device Selection Screen (see figure 6) shows those devices supported by the driver. The application does not detect the physical hardware. You may choose only one type of device to install since Windows NT supports only one type of a device at a time. After you’ve selected the device you want to install, click “Next”.
BarcoMed software driver installation 4. The next screen (figure 8) displays the device that will be installed. If you want to change your selection, click “Back” and you will see the previous screen. To begin installation, click “Next”. If you want to end the installation without installing the driver, click “Cancel” and the Wizard will exit. Once you click “Next”, you cannot cancel the driver installation.
BarcoMed software driver installation Figure 10 6. Remove your ImageTile Software CD from its drive and click “Yes” to confirm reboot (see figure 11). Figure 11 7. When your computer restarts, select “NT Version 4.0 (VGA Mode)”. Log in using an account with administrator privileges.
BarcoMed software driver installation If you are installing one 3MP2FH in portrait mode, select “3072x2048x256”. This will set the output resolution for each display to “1536x2048x256”. For a two-card, quad-head configuration, select “6144x2048x256”. Select “OK”. 4. Select the “Test” button and click on “OK” to test the display. You will be asked if it displayed correctly. If the test pattern displays correctly, select “Yes”. If not, select “List all Modes” and try selecting another mode. 5.
BarcoMed software driver installation Note: The system shown in figure 12 is a single BarcoMed 3MP2FH Imaging Board, no 3rd party VGA card configuration, your system may look different. Installing the Driver Using the Windows NT 4.0 Display Properties Control Panel SPECIAL NOTE: Prior to installing the BarcoMed Display Drivers you MUST install the BarcoMed Imaging Board(s), connect the ImageTile display panel(s) to the card(s) and turn the ImageTile display panel(s) on.
BarcoMed software driver installation 15. You will be asked if you want to restart your computer. If you are using an ImageTile Software CD, remove it from its drive and select “Yes”. 16. When the system comes back up, select “NT Version 4.0 (VGA Mode)”. Log in using an account with administrator privileges.
BarcoMed software driver installation Installing the BarcoMed 3MP2FH Windows 2000 Display Driver Installing the Driver Using the BarcoMed Driver Installation Wizard SPECIAL NOTE: Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board(s), connect the ImageTile display panel(s) to the card(s), and turn the ImageTile display on.
BarcoMed software driver installation Continue to click “Cancel” until Windows 2000 stops launching the “Found New Hardware Wizard - Video Controller”. 4. Windows 2000 may advise you that it has finished installing all the new devices in your system and that you must reboot your system in order for the changes to take effect. If it does, Click “No”. 5. Insert your ImageTile Software CD into your computer’s CD drive. The “BarcoMed Driver Installation Wizard” should start automatically.
BarcoMed software driver installation the user clicks “Finish” or “Cancel”. Select the devices you want to install, click “Next”. Figure 16 If you selected a device with an existing driver, the existing driver’s version will be compared against the version of the driver you are installing. If the existing driver’s version is newer than the one you are installing, the Wizard will warn you that the current driver is newer than the one you are installing (see figure 17).
BarcoMed software driver installation Figure 18: DualView Disabled Figure 19: DualView Enabled If DualView is not enabled, you will see a single virtual screen in the display properties dialog for both heads of a Imaging Board. If DualView is enabled, you will see two virtual screens in the dialog box on the Settings Tab of the Display Properties Control Panel, one for each head of the Imaging Board.
BarcoMed software driver installation checkbox next to “Enable the DualView device?”, and click “Next”. If you do not wish to enable DualView simply click “Next” to continue. Figure 20 9. The screen shown in figure 21 displays the device(s) that will be installed. If you want to change your selection, click Back and you will see the previous screen. To begin installation, click “Next” to continue. If you want to end the installation without installing the driver, click “Cancel” and the wizard will exit.
BarcoMed software driver installation Figure 22 11. While the driver is being installed, the screen shown in figure 23 will be visible. Figure 23 12. For each display supported by your ImageTile imaging board(s) the Wizard will display the screen shown in figure 24. Click “Yes” to continue. Figure 24 13. If the Wizard has successfully installed the drivers for all of the displays supported by your BarcoMed 3MP2FH imaging board(s), the Wizard will prompt you to reboot your system (see figure 25).
BarcoMed software driver installation restart your computer at a later time. If the installation failed, click “Finish” to exit the Wizard (see figure 27). Figure 25 Windows will warn you that you must restart your computer before the new settings will take effect (see figure 26). Click Yes to restart your computer. When your computer restarts, log in using an account with administrator privileges.
BarcoMed software driver installation Figure 27 Setting the Resolution of Your ImageTile Display Panel with DualView Disabled 1. To set the resolution for your ImageTile display panel(s), right click on the desktop and select “Properties”. Select the “Settings” tab (see Figure 28 on the next page). Now select the rectangle that represents the BarcoMed 3MP2FH Imaging Board you are working with.
BarcoMed software driver installation Click “OK” on the bottom of the Adapter Control Panel. If the “OK” button on the bottom of the Adapter Control Panel is not visible, press the “Tab” key once and then “Enter” to select “OK”. 4. Click “OK” in the “Windows will now apply your new desktop settings” dialog box. Your high resolution display(s) should now synchronize and display the Windows desktop. 5. Click “Yes” when asked, “Your desktop has been reconfigured.
BarcoMed software driver installation Setting the Resolution of Your ImageTile Display Panel with DualView enabled Once you have completed the installation of the separate screens with DualView, you need to set the resolution for each display. Both screens of each imaging board cannot be enabled at the same time unless their display properties match. 1. To set the resolution for your ImageTile display panel(s) under DualView, right click on the desktop and select “Properties”. 2.
BarcoMed software driver installation To set the resolution of the second ImageTile display attached to the BarcoMed 3MP2FH Imaging Board you are working with, go back to the “Settings” tab of the “Display Properties Control Panel”. Attach the display you detached in step 2 above, by right clicking on the rectangle that represents it and selecting “Attached”. Now repeat steps 3 – 7 above for this display.
BarcoMed software driver installation Disabling DualView under Windows 2000 DualView can be disabled on a BarcoMed Imaging Board through the Monitor Configuration section of the Barco Metheus Configuration Tab by following the steps listed below. 1) Open the “Display Properties Control Panel” by right clicking on the desktop, then select “Properties”. 2) Click on “Settings” tab.
BarcoMed software driver installation Re-enabling DualView under Windows 2000 If you have disabled DualView using the method described on the previous page (or if you installed the driver with DualView disabled) and decide you want to re-enable it, follow the steps listed below. 1) Open the “Display Properties Control Panel” by right clicking on the desktop, then select “Properties”. 2) Click on “Settings” tab.
BarcoMed software driver installation Installing the Driver Using the Windows 2000 Found New Hardware Wizard SPECIAL NOTE: Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board(s), connect the ImageTile display panel(s) to the card(s), and turn the ImageTile display on. Refer to the Hardware Installation section of this manual for instructions on installing the BarcoMed Imaging Board(s) and connecting them to the ImageTile display panel(s).
BarcoMed software driver installation 8. The “Start Device Driver Installation” dialog box will appear. Click “Next”. 9. Windows will warn you that a digital signature was not found. Click “Yes” to continue the installation. 10. When the drivers have finished installing, click “Finish” on the “Completing Found New Hardware Wizard” page. If you are installing a single BarcoMed 3MP2FH Imaging Board, Windows 2000 will now prompt you to reboot your system. Click “Yes”.
5. BarcoMed software driver installation Select the radio button beside “Display a list of the known drivers for this device so that I can choose a specific driver”. Click “Next”. 6. In the “Hardware Type” page of the wizard, highlight “Display Adapters” and then click “Next”. 7. In the “Select a Device Driver” page of the wizard click “Have Disk”. Insert your ImageTile Software CD or browse to the location of your driver and Click “OK”. 8.
BarcoMed software driver installation Installing DualView under Windows 2000 DualView allows a dual head graphics board to display two separate desktops, one for each monitor instead of a single virtual desktop that spans across both monitors. Figures 32 and 33 below illustrates the difference between running without and with DualView enabled under Windows 2000. DualView is a feature that is supported by Windows XP.
BarcoMed software driver installation Figure 33: Windows 2000 Display Properties Control Panel with DualView enabled. Note: The system shown in figure 33 above is a dual-head, single BarcoMed 3MP2FH Imaging Board, no 3rd party VGA card, DualView enabled configuration. Rectangles “1” and “2” represent the two ImageTile displays of a single board/dual head installation. Your configuration may look different.
BarcoMed software driver installation 6. In the “Find New Hardware” page of the wizard select the radio button beside “No, I want to select the hardware from a list” and click “Next”. 7. In the “Hardware Type” page of the wizard, highlight “Display Adapters” and then click “Next”. 8. In the “Select a Device Driver” page of the wizard select “BARCO Metheus” in the Manufacturers column and “BarcoMed 3MP2FH” in the Models column. Click “Next”. 9. The “Start Hardware Installation” dialog box appears.
BarcoMed software driver installation If necessary detach the second display of the BarcoMed 3MP2FH Imaging Board you are working with by right clicking on the rectangle that represents it and deselect “Attached”. Click the “Apply” button. Note: Since Windows 2000 will not let you detach the primary display, you may need to temporarily make another display the primary display. 3. For the display which is still attached click on the “Advanced” Button. 4.
BarcoMed software driver installation Installing the BarcoMed 3MP2FH Windows XP Display Driver Installing the Driver Using the BarcoMed Driver Installation Wizard SPECIAL NOTE: Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board(s), connect the ImageTile display panel(s) to the card(s), and turn the ImageTile display on.
BarcoMed software driver installation 6. Windows XP may also tell you that it has finished installing new devices and may ask you if you want to restart your computer. Click “No”. 7. Insert your ImageTile Software CD into your computer’s CD drive. The “BarcoMed Driver Installation Wizard” should start automatically. If it doesn’t start within 5 minutes, browse the contents of your ImageTile Software CD and double click on the file: “NTDriverInstaller.exe” to start the Wizard. 8.
BarcoMed software driver installation ImageTile Software CD does not support the installed devices, the dialog box will be empty, and program will exit when the user clicks “Finish” or “Cancel”. Select the devices you want to install, click “Next”. Figure 37: Supported Devices Screen 10. If you selected a device with an existing driver, the existing driver’s version will be compared against the version of the driver you are installing.
BarcoMed software driver installation Figure 39: DualView Enabled Figure 40: DualView Disabled If DualView is enabled, you will see two virtual screens in the dialog box on the Settings Tab of the Display Properties Control Panel, one for each head of the Imaging Board. If DualView is not enabled, you will see a single virtual screen in the display properties dialog for both heads of a Imaging Board. If you wish to enable simply click “Next” to continue.
BarcoMed software driver installation next to “Enable the DualView device.”, and click “Next” to continue. Figure 41 12. The screen shown in figure 42 displays the device(s) that will be installed. If you want to change your selection, click Back and you will see the previous screen. To begin installation, click “Next” to continue. If you want to end the installation without installing the driver, click “Cancel” and the Wizard will exit. Figure 42 13.
BarcoMed software driver installation Figure 43 While the driver is being installed the screen shown in figure 44 will be visible. Figure 44 14. During the driver installation Windows XP will warn you that the driver has not passed Windows XP Logo Testing (see figure 45). Figure 45: Windows XP Windows Logo Testing Warning Screen Click “Continue Anyway” to continue installing the driver or click “STOP the Installation” to cancel the driver installation.
BarcoMed software driver installation 15. If the Wizard has successfully installed the drivers for all of the displays supported by your BarcoMed 3MP2FH imaging board(s), the Wizard will prompt you to click “Finish” (see figure 46). Clicking on “Finish” will exit the Wizard and restart your computer now. Click “Cancel” to exit the Wizard and restart your computer at a later time.
BarcoMed software driver installation Setting the Resolution of Your ImageTile Display Panel with DualView Enabled By default DualView is enabled when you install the BarcoMed Windows XP driver. DualView is a Windows XP feature that allows a dual headed imaging board with a single graphics chip to display two separate desktops, one for each monitor instead of a single virtual desktop that spans across both monitors.
BarcoMed software driver installation Figure 49: Windows XP Display Properties Settings Tab for the 3MP2FH with DualView enabled Note: The system shown in figure 49 above is a dual-head, single BarcoMed 3MP2FH imaging board, no 3rd party VGA card configuration. Your system may look different.
BarcoMed software driver installation 3. Select the “Adapter” tab and then click on the “List All Modes…” button. Select the resolution and refresh rate that your ImageTile display supports from the dialog box and click “OK”. Note: The resolutions shown will be based on the number of heads the imaging board supports. For example: The BarcoMed 3MP2FH Imaging Board supports two ImageTile display panels.
BarcoMed software driver installation Disabling DualView under Windows XP DualView can be disabled on a BarcoMed Imaging Board through the Monitor Configuration section of the Barco Metheus Configuration Tab by following the steps listed below. 1. Open the “Display Properties Control Panel” by right clicking on the desktop, then select “Properties”. 2. Click on “Settings” tab.
BarcoMed software driver installation Re-enabling DualView under Windows XP If you have disabled DualView using the method described on the previous page and decide you want to re-enable it, follow the steps listed below. 1. Open the “Display Properties Control Panel” by right clicking on the desktop, then select “Properties”. 2. Click on “Settings” tab. Double click on the rectangle that represents the BarcoMed Imaging Board you are working with to bring up its property page.
BarcoMed software driver installation Installing the Driver Using the Windows XP Found New Hardware Wizard SPECIAL NOTE: Prior to installing the BarcoMed drivers you MUST install the BarcoMed Imaging Board(s), connect the ImageTile display panel(s) to the card(s), and turn the ImageTile display on. Refer to the Hardware Installation section of this manual for instructions on installing the BarcoMed Imaging Board(s) and connecting them to the ImageTile display panel(s).
BarcoMed software driver installation until you have installed the drivers for all of the BarcoMed 3MP2FH boards in your system. Prior to installing the drivers for any additional imaging boards, we strongly recommend that you set the resolution for the monitors connected to the first boards installed. If you don’t, Windows XP may pick a resolution that is not supported by your display and you will need to reboot in VGA mode to continue.
BarcoMed software driver installation system when asked and set the resolution of the first monitor controlled by the first BarcoMed 3MP2FH. You can then install the remaining adapters associated with all of the BarcoMed 3MP2FH boards installed in your system. Repeat steps 3 – 11 until you have installed all of the adapters.
BarcoMed software driver installation (This page intentionally left blank.
BarcoMed software driver installation BARCO METHEUS CONFIGURATION TAB Introduction After the BarcoMed 3MP2FH Windows Display Driver is installed, a new Display Properties tab is available for configuring special features of the BarcoMed 3MP2FH imaging board. Please note that you must have logged on to Windows using an account with administrator privileges in order to use the BARCO Metheus Control Panel to change any display settings.
BarcoMed software driver installation Figure 54: Configuration Tab under Windows 2000 Figure 55: Configuration Tab under Windows XP System manual ImageTile 80
BarcoMed software driver installation Status Displays the current BarcoMed Imaging Board, driver, and the currently selected display resolution. Graphics Board This displays the current BarcoMed Imaging Board. Driver Version This displays the current BarcoMed driver version. Resolution This displays the currently selected display resolution.
BarcoMed software driver installation index 10 to 245 contain the missing gray values so that the palette has the full 256 gray values within it. Please note that dithering is not permitted while in this mode. The Enable Dithering check box will be grayed-out, and dithering will be automatically disabled regardless of whether this check box is checked. This complies with the Windows standard interface method.
BarcoMed software driver installation your application requires this “Static Gray Palette with NO System colors” mode, contact your application provider. Drawing Modes You can choose one or both of the following Drawing Modes: Enable DirectDraw This option allows the user to enable or disable DirectDraw. DirectDraw is a software interface that provides direct access to display devices while maintaining compatibility with the Windows graphics device interface (GDI).
BarcoMed software driver installation one row” option from the pull-down list. This would cause the Windows virtual desktop to be resized to fit on the three monitors, and you can move your cursor horizontally from one screen to the other. If “Custom Configuration” is displayed, it means that the current monitor configuration was set via the registry and it doesn’t agree with any of the configurations that the display control panel supports. Contact Barco Medical Imaging Systems for further information.
BarcoMed software driver installation BARCO METHEUS HARDWARE CONFIGURATION TAB Introduction The BARCO Metheus Hardware Configuration Tab is used for gathering information about BarcoMed imaging boards. For all BarcoMed imaging boards it will display PCI information. In addition for BarcoMed imaging boards based on the AURA video chipset it will also display information about the Firmware installed on the board.
BarcoMed software driver installation To access the BARCO Metheus Hardware Configuration Tab do the following: 1. Open the “Display Properties Control Panel” by right clicking on the desktop, then select “Properties”. 2. Under Windows NT 4.0, Click on the “BARCO Metheus Hardware Configuration” Tab. (see figure 56, below). Under Windows 2000 and Windows XP, click on the “Settings” tab. Double click on the rectangle that represents the BarcoMed 3MP2FH to bring up its property page.
BarcoMed software driver installation Figure 57: BARCO Metheus Hardware Configuration Tab under Windows 2000 and Windows XP Using The BARCO Metheus Hardware Configuration Tab Device Displays the current BarcoMed Imaging Board, driver, and the currently selected display resolution. Identify Device: This button is for BarcoView Metheus internal use only and is greyed out.
BarcoMed software driver installation PCI Information Device ID: Displays the device’s PCI Device ID number. Vendor ID: Displays the device manufacturer’s PCI Vendor ID number. Subsystem ID: Displays the device’s PCI Subsystem ID number. SubsystemVendorID: Displays the device’s PCI Subsystem Vendor ID number. VGA Status: Displays whether the VGA capabilities of the BarcoMed board are enabled or disabled.
BarcoMed software driver installation “Update Device...” Button: Clicking this button will run the BarcoMed Hardware Configuration Wizard. This program allows the user to flash update the firmware stored in the ROM of the currently selected BarcoMed imaging board. The BarcoMed Hardware Configuration Wizard is a “wizard style” application that uses dialog boxes to guide the user through the flash update procedure. The user will be prompted to select a firmware update file to use for the update.
BarcoMed software driver installation (This page intentionally left blank.
BarcoMed software driver installation BARCO METHEUS DPMS OVERVIEW Introduction The Barco Metheus DPMS (Display Power Management Signaling) Screen Saver allows the user to set power and monitor saving features for medical monitors driven by BarcoMed Imaging Boards. At the end of the work day, the monitor will enter certain DPMS states as requested by the imaging board. This is accomplished through standardized signals between the monitor and imaging board. The default DPMS state is the Off state.
BarcoMed software driver installation BarcoMetheus DPMS Screen Saver Options From the “Barco Metheus DPMS Screen Saver Control Panel” you can change many DPMS screen saver elements simultaneously. The DPMS screen saver elements in each scheme are work schedule, work day screen saver, DPMS settings after work day, and many additional options. Current Scheme Lists the three “DEFAULT” schemes which you can use as they are. Or you can modify them to meet your office’s schedule.
BarcoMed software driver installation work day. This “regular” screen saver and its settings can be chosen from the “Screen Saver During Work Day” section. We recommend using an all black screen saver, such as the “Barco Metheus Blank Screen” saver, for the longest phosphor life. On LCD based monitors, such as the Barco ImageTile displays, it is not necessary to invoke a screen saver as there is no CRT phosphor to preserve.
BarcoMed software driver installation DPMS State Pow er Savings Monitor Recovery Time On None N/A Stand-by Minimal Short Suspend Substantial Longer Off Maximum Longest Monitor Settings Select the amount of time the monitor requires to warm-up. Since all CRT based monitors require some warm-up time before they are at full performance, this ensures that the monitor is ready for use at the beginning of the work day. If you have a Barco Medical Monitor, select “Barco Quick Start.
BarcoMed software driver installation 2. Use Windows Explorer to navigate to the following folder: [CD drive]:\DPMS_ScreenSaver\: On Windows NT 4.0 systems install the Windows Installer by double clicking on the file “instmsiw.exe”. On Windows 2000 and Windows XP systems install the Windows Installer by double clicking on the file “instmsia.exe”. 3. Restart your system if prompted to do so. 4. Now install the DPMS Screen Saver by double clicking on the file: 5. “[CD drive]:\DPMS_ScreenSaver\setup.exe”.
BarcoMed software driver installation displayed saying “you must have administrator rights to modify a default scheme.” If an administrator saves a scheme using an existing default scheme name, a message is displayed to tell the user that the modification is saved to a default scheme and will be visible to all users. If the administrator saves a scheme using a new name, then the user is asked if the scheme should be saved as a default scheme or a private scheme.
BarcoMed software driver installation Figure 58: Windows NT 4.
BarcoMed software driver installation Figure 59: Windows 2000 Screen Saver Tab System manual ImageTile 98
BarcoMed software driver installation Figure 60: Windows XP Screen Saver Tab System manual ImageTile 99
BarcoMed software driver installation Figure 61: Barco Metheus DPMS Setting Control Panel To create a new scheme by modifying one of the three default schemes please do the following. 1. Open the “Display Properties Control Panel” by right clicking on the desktop and then select the “Screen Saver” tab. 2. Select the “BarcoMetheus DPMS Screen Saver” in the “Screen Saver” drop down menu if it is not already selected. 3. Click on the “Settings” button.
BarcoMed software driver installation 5. Set the Work Schedule by setting the beginning and ending time of your work day for each day of the week. 6. Select the screen saver you wish use during the work day in the “Screen Saver During Work Day” section. 7. Select the amount of time you wish to spend in the Stand-By and Suspend states after the work day has ended. Please note that after the time specified has elapsed when you are in Stand-By or Suspend, you will automatically go into the Off state. 8.
BarcoMed software driver installation For Windows 2000 and Windows XP Systems 1. Launch the Windows Control Panel. 2. Then double click the on “Add/Remove Programs”. 3. Highlight “DPMS Screen Saver” in the “Currently Installed Programs” window. Click the “Change/Remove” button. 4. The Windows Installer will ask if you are sure you want to remove this program, click “Yes”. 5. When the Windows Installer has finished removing the program, click “Close” to exit the Add/Remove Program Control Panel. 6.
SETTING UP SENTINEL System manual ImageTile 103
Sentinel setup (This page intentionally left blank.
Sentinel setup INTRODUCING SENTINEL What is Sentinel? The built-in SENTINEL® board and software turn IMAGETILE ® into an intelligent, web-enabled device, which can be addressed via the facility network through a user-friendly browser interface. Thanks to Sentinel, you can consult a number of the panel's settings online, on any PC connected to the network. Moreover, Sentinel can generate e-mails to user-defined addresses in case a setting exceeds a warning or error tolerance level.
Sentinel setup INSTALLING THE SENTINEL SETUP SOFTWARE To install the Sentinel Setup software, proceed as follows: 1 Exit all open programs. 2 Insert the Sentinel Setup CD-ROM in the CD-ROM drive. 3 Open the Sentinel Setup CD-ROM. 4 Double-click on Setup.exe. The Setup application starts. 5 Click on the Next> button. 6 Read the License agreement on the screen very carefully. Scroll down to read the complete text.
Sentinel setup ENTERING INTERNET PROTOCOL ADDRESS PROPERTIES Entering address properties for the first time Note: When you enter the address properties for the first time, there is no time limit for entering the address properties. But if the address properties have already been entered before (which you cannot distinguish when you start Sentinel Setup), there is a time limit of 2 minutes for entering the properties.
Sentinel setup Entering a fixed IP-address Proceed as follows: 1 Make sure the connected computer supplies an image to the ImageTile panel. 2 Make sure the ImageTile is connected to the network, using the network connector on the ImageTile itself. 3 Run the application "sentinel.setup" from the Start -> Programs -> Sentinel menu. The Sentinel Network Configuration dialog appears. 4 Check the option No DHCP server available. 5 Enter valid addresses in the fields IP-address, Subnet Mask and Gateway.
Sentinel setup 10 As a result, the computer will try to establish communication with the ImageTile panel. When the communication has been established, the following message appears: Important: Write down the IP-address for future reference: You will need it to browse to the ImageTile later. Click on OK to close the message. Then click on Cancel in the Sentinel Network Configuration dialog to finish.
Sentinel setup Acquiring an IP-address dynamically Proceed as follows: 1 Make sure the connected computer supplies an image to the ImageTile panel. 2 Make sure the ImageTile is connected to the network, using the network connector on the ImageTile itself. 3 Run the application "sentinel.setup" from the Start -> Programs -> Sentinel menu. The Sentinel Network Configuration dialog appears. 4 Check the option DHCP server available. 5 Enter the IP-address of your mail server in the field Mailhost IP.
Sentinel setup Important: The message that the software returns, mentions the IP-address of the Sentinel board. Write down the IP-address for future reference: You will need it to browse to the ImageTile later. Click on OK to close the message. Then click on Cancel in the Sentinel Network Configuration dialog to finish. 9 When the communication with the ImageTile failed, the following message appears: Click on OK to close the message and enter the correct data in the dialog.
Sentinel setup Changing the address properties When the ImageTile already has got an IP-address, you can change the Internet Protocol address properties using the Sentinel Setup software. For more information about the different possibilities in entering the address properties, please refer to the previous chapter "Entering address properties for the first time". To change the address properties, proceed as follows: 1 Make sure the connected computer supplies an image to the ImageTile panel.
Sentinel setup CONNECTION PROBLEMS In this chapter you may find some hints to help you in case the computer cannot connect to the ImageTile after entering or changing the address properties. The same hints may help in case you cannot remotely connect to the ImageTile with your web browser. Re-enter the address properties After entering the address properties, the connection with the ImageTile may fail because you have entered wrong data. So, you can try to repeat the procedure and enter the correct data.
Sentinel setup Looking up the ImageTile's IP-address When trying to connect remotely to the ImageTile using your web browser, the connection may fail because you may have entered the wrong IP-address in the browser's address field. When you have forgotten the ImageTile's IP-address, you can look it up on the computer connected to the ImageTile. Therefore, start Windows Explorer on that computer and browse to the folder where the Sentinel Setup application is installed.
IMAGETILE WEB CONTROL System manual ImageTile 115
ImageTile web control (This page intentionally left blank.
ImageTile web control INTRODUCTION The ImageTile Web Control allows you to remotely connect to the ImageTile panel and to: - Check a number of the ImageTile's parameters - Define a warning and error tolerance for some of the ImageTile's parameters - Enter the mail addresses to which a mail must be sent automatically in case one of the ImageTile's parameters exceeds the warning or error tolerance - Enter the Sentinel "From" address that will appear on the warning and error mails Important: The Image
ImageTile web control When the connection fails - When the connection fails, you have probably entered a wrong address or host name. Try entering the address or host name again in the web browser. - Check that both the ImageTile and the computer on which you wish to establish the connection, are connected to the network. - When the connection still fails, please refer to the chapter "Connection problems" in the previous section.
ImageTile web control ENTERING THE SENTINEL MAIL ADDRESS In the ImageTile Web Control pages, you must enter the "From" address that will be used in warning and error mails generated by Sentinel. We assume you have established connection with the ImageTile and your web browser displays the Sentinel main page. Proceed as follows: 1 In the Sentinel main page, click on "Sentinel Init". The Sentinel init page appears.
ImageTile web control SETTING SENTINEL REPORTING SETTINGS Use this function to define the conditions when an automatic mail must be generated and to which person(s) the mail must be sent. This mail will be sent when a particular parameter exceeds a predefined threshold. We assume you have established connection with the ImageTile and your web browser displays the Sentinel main page. Proceed as follows: 1 In the Sentinel main page, click on "Define Sentinel Task Settings".
ImageTile web control 3 To change the interval of checking the parameter, click on the displayed interval and use the up and down button to change the interval. 4 To edit the reporting settings, click on "Edit". - Fill in the Warning and Error threshold values. Typical values are 2% for error and 5% for warning tolerance. - Fill in the e-mail recipient address in the "To" fields.
ImageTile web control CHECKING PANEL PARAMETERS ON-LINE Use this function to check panel parameters on-line. We assume you have established connection with the ImageTile and your web browser displays the Sentinel main page. Proceed as follows: 1 In the Sentinel main page, click on "Go to ImageTile Control Functions". The Control Functions page appears.
ImageTile web control 2 Select the check you wish to perform. You can perform the following checks: Get the firmware version ...... Returns the firmware versions for each tile Check the backlight ............. Returns the backlight reserve for each tile, compared to the maximum backlight reference of 500 cd/m², calibrated. Get the luminance ................ Returns the luminance value for each tile Get the display runtime ........ Returns the total runtime of each tile Get the backlight runtime .....
ImageTile web control 2 Select "Reboot Sentinel" 3 Sentinel now reboots, allowing you to change the Internet Protocol address properties. More information about this, you can find in the previous section "Setting up Sentinel". If you do not wish to change the address settings You may have selected the "Reboot Sentinel" function without the intention to assign a new IP-address. In that case, you do not have to do anything. Sentinel will reboot.
MEDICAL SOFTWARE INSTALLATION AND USAGE System manual ImageTile 125
MediCal software installation and usage (This page intentionally left blank.
MediCal software installation and usage MEDICAL SOFTWARE INSTALLATION Install MediCal on the PC. Follow the instructions from the MediCal User Guide. Important: Do not forget you have to have Administrator privileges to install or uninstall MediCal. OPTICAL SENSOR CONNECTION If you are using an X-Rite DTP92 sensor for conformity calibration and consistency check, connect the sensor to one of the display's Sensor plugs or to a free PC COM port.
MediCal software installation and usage (This page intentionally left blank.
APPENDIX System manual ImageTile 129
Appendix (This page intentionally left blank.
Appendix MAINTENANCE Panel Take care not to damage or scratch the panel. Clean with a soft woolen or cotton towel. Use a watery solution or a mild commercial glass cleaning product. Cabinet Do not use chemical cleaning products, benzene, toluene, xylene or other solvents. Clean with a soft cloth dampened with mild detergent and water. Repeat with water only and wipe dry with a dry cloth.
Appendix TROUBLESHOOTING Pixel Faults Permanently dark or bright pixels can happen to TFT displays. 20 or less permanently dead pixels do not make out a good case for exchanging the unit. Please contact our Customer Service Department if the number of pixel faults exceeds the above-mentioned figure.
Appendix TECHNICAL SPECIFICATIONS Picture panel (per head) 20.8-inch diagonal viewable screen TFT (thin film transistor) active matrix, greyscale liquid crystal display Coating High efficiency anti-reflective coating (HEA - glass transparency: 96%) Resolution (per head) Native: 1536 x 2048 Display area (H x V) (per head) 423.
Appendix Pixel Pitch 0.207 mm (H) x 0.207 mm (V) Controls Central stand-by button, DPMS compliant Front access to all connectors (USB) Input connectors DVI dual channel Power supply Dynamic 90 -264 Vac (47-63 Hz) Power consumption (nominal) Dual-head +/- 140 W, Quad-head +/- 290 W Configuration Standard wall-mounting kit included; for other mounting options, please consult Barco Safety This apparatus conforms to: UL 2601-1, c-UL CAN/CSA-22.2 No. 601.
Appendix 511.9 mm Dimensions BARCO 95.88 mm 511.9 mm 766.6 mm BARCO 1489.4 mm NOTICE: DUE TO OUR POLICY OF CONTINUOUS PRODUCT IMPROVEMENT, THE ABOVE SPECIFICATIONS ARE SUBJECTED TO CHANGE WITHOUT NOTICE. BARCO SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN; NOR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES WHATSOEVER RESULTING FROM FURNISHING, PERFORMANCE OR USE OF THIS MATERIAL.
Appendix System manual ImageTile 136