Instruction manual
50 ImagePRO-II • User’s Guide
4. Menu Orientation
Configuring Inputs
If you have used all 64 input configurations, the following message appears.
Figure 4-20. Library Full Message
When you see this message, press ESC and go to the Delete Config Submenu
to delete a different configuration file. Then save the new configuration.
oÉëÉííáåÖ=~å=fåéìí=`çåÑáÖìê~íáçå
From the Input Menu, select Reset Config to remove all user-defined configuration
settings for the selected input, and restore the input’s parameters from the system’s internal
library values.
When you select Reset Config, you are prompted to reset (SEL) or continue without
resetting (ESC).
If the current input format was derived as a “best guess,” those best-guess values are
restored when you press SEL.
oÉÅ~ääáåÖ=~å=fåéìí=`çåÑáÖìê~íáçå
The Recall Config Submenu lets you assign a user-defined configuration to a selected
input. The new configuration must match the current input’s format and type.
Figure 4-21. Recall Config Submenu
To recall a configuration for an input, use the following procedure:
1. Select the input to which you want to assign a configuration.
2. On the Input Menu, select Recall Config.
3. With the navigation cursor pointing to the input file name, press SEL. The
navigation cursor changes to the edit cursor and a list of files appears.
SAVE CONFIG AS
LIBRARY FULL
<ESC> = Continue
Note
Resetting configuration parameters does not change which
configuration file is associated with the input — it simply
assigns the reset parameters to the existing configuration file.
RECALL CONFIG
> File1
Recall Config