Installation Manual
1. Liquid Cooling Circuit
Block diagram of the cooling circuit
Engine
Pump
Vane
Outlet
Inlet
Expansion Vat
Manometer
Heat
Exchanger
Light Pipe
entry
Pressure relief
valve (3 Bar)
Vane
Outlet
Inlet
Waterflow Sensor
to SMPS Control
Image 1-2
Block diagram cooling c ircuit
Order info liquid cooling
Order number
Description
R395198K
Complete liquid cooling refill kit. Includes tubes, valved fittings, syringe, air pump, plastic bottle of 1 liter
filled with c ooling liquid and one empty plastic bottle of 1 liter.
B1909086K
Two bottles of 1 liter filled with cooling liquid. (no additional tools)
1.3 Diagnostics
General
Over extended periods there may be small losses of pressure in the liquid cooling system of the projector. It is there for recommended
to check the pressure at regular intervals. In case the pressure drops below 0,5 bar it is recom m ended to restore the pressure of
the liquid cooling system.
CAUTION: In case of a rapid loss in pressure check the liquid cooling circuit for leakage. Solve the problem
before starting up the projector.
Troubleshooting cooling loop
• Any significant or ra pid drop in pressure indicates a leakage of liquid. If this be the case, verify w hether the circuit shows any
visible sign of liquid leakage.
• As critical components rely o n this liquid cooling, it is essential that an y leakage is detected timely.
• Periodic c hecking of the liquid cooling pressure is essential to guarantee overall good performance of the projector and the
pump.
• The factory pressure preset is a pproximately 1 bar in the ’Projector Off’ status at a room temperature of 25 °C. T his may drop
slightly during operation.
R59770032 COOLING LIQUID REFURBISHMENT 07/12/2006