Coronis 5MP Mammo Installation & User Manual
(This page intentionally left blank.
Copyright notice Copyright This document is copyrighted. All rights are reserved. Nor this document, nor any part of it, may be reproduced or copied in any form or by any means - graphical, electronic, or mechanical including photocopying, taping or information storage and retrieval systems without written permission of Barco © 2008 Barco N.V. All rights reserved.
(This page intentionally left blank.
Table of Contents Table of Contents Preface........................................................................................ 9 Environmental information............................................................... 13 Safety Instructions............................................................................. 16 Explanation of symbols ..................................................................... 19 Recommendations for using your display system...........................
Table of Contents Status .......................................................................................... 66 Palette Mode .............................................................................. 67 Drawing Modes .......................................................................... 70 Monitor Configuration ................................................................ 72 Barco DPMS Screen Saver ................................................................. 73 Introduction ..........
Table of Contents Front glass........................................................................................ 106 Cabinet ............................................................................................. 107 LCD panel ......................................................................................... 108 Troubleshooting...................................................................... 111 General tips.............................................................................
Table of Contents (This page intentionally left blank.
Preface 9
Preface (This page intentionally left blank.
Preface Notice Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know. Barco software products are the property of Barco. They are distributed under copyright by Barco N.V. or Barco, Inc., for use only under the specific terms of a software license agreement between Barco N.V. or Barco Inc.
Preface • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. Canadian notice This ISM device complies with Canadian ICES-001. Cet appareil ISM est conforme à la norme NMB-001 du Canada.
Environmental information Environmental information Disposal Information This product consists of devices that may contain mercury, which must be recycled or disposed of in accordance with local, state, or country laws. (Within this system, the backlight lamps in the monitor display contain mercury.) This equipment has required the extraction and use of natural resources for its production. It may contain hazardous substances for health and environment.
Environmental information Information for China ROHS compliance Table of toxic and hazardous substances/elements and their content, as required by China’s management methods for controlling pollution by electronic information products Toxic or hazardous Substances and Elements Part Name Pb Hg Cd Cr6+ PBB PBDE Metal parts O O O O O O Plastic parts O O O O O O PCB or PCBA O O O O O O LCD panel X X O O O O Power supply/adapter X O O O O O Power cable X O O O O O
Environmental information LCD Monitor 零部件名稱 有毒有害物質或元素 铅 汞 镉 (Pb) (Hg) (Cd) 金属机构件 O O O 塑料机构件 O O O O O O 电路板组件 * X X O 液晶面板 X O O 电源模块 / 适配器 X O O 电源线 O O O 外部信号连接线 六价铬 (Cr6+) O O O O O O O 多溴联苯 多溴二苯醚 (PBB) (PBDE) O O O O O O O O O O O O O O *: 电路板组件包括印刷电路板及其构成的零部件,如电阻、电容、集成电路 、连接器等 ○:表示该有毒有害物质在该部件所有均质材料中的含量均在 《电子信息产品中有 毒有害物质的限量要求标准》规定的限量要求以下 ×:表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 《电子信息产品 中有毒有害物质的限量要求标准》规定的限量要求; 但是上表中打 “×”的部件,其含量超出是因为目前业界还没有成熟的可替代的技术 15
Safety Instructions Safety Instructions General Recommendations Read the safety and operating instructions before operating the display. Retain safety and operating instructions for future reference. Adhere to all warnings on the display and in the operating instructions manual. Follow all instructions for operation and use.
Safety Instructions • The medical approved DC power supply must be powered by the AC mains voltage. Power cords: • Utilize a UL-listed detachable power cord, 3-wire, type SJ or equivalent, 18 AWG min., rated 300 V min., provided with a hospital-grade type plug 5-15P configuration for 120V application, or 6-15P for 240V application. • Do not overload wall outlets and extension cords as this may result in fire or electric shock. • Mains lead protection (U.S.
Safety Instructions Operating precautions Continuous operation of the display with the same image may result in some image sticking on the LCD panel. Over 10 hours operation with the same image content is not recommended. Switching on DPMS on display and PC and activating a good screen saver may decrease the risk of image sticking (image retention). This apparatus conforms to: CE0120 (MDD 93/42/EEC class IIb product), IEC 60601-1, UL 60601-1, CAN/CSA C22.2 No. 601.
Explanation of symbols Explanation of symbols Symbols on the display and/or power supply On the display or power supply, you may find the following symbols: Indicates compliance to the essential requirements of the Directive 93/42/EEC Indicates the display is approved according to the UL regulations or Indicates the display is approved according to the c-UL regulations or Indicates the display is approved according to the DEMKO regulations Indicates the display is approved according to the CCC regulations
Explanation of symbols Consult the operating instructions Indicates this apparatus must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive Symbols used throughout the manual: 20 Warning: Risk of injury to human beings Caution: Risk of damage to the product Important notice or remark Note Hint, tip Additional information
Recommendations for using your display system Recommendations for using your display system 1. Optimize the lifetime of your display Enabling the Display Power Management System (DPMS) of your display (in the display’s Settings menu) will optimize its diagnostic lifetime by automatically switching off the backlight when the display is not used for a specified period of time. By default, DPMS is enabled on your display, but it also needs to be activated on your workstation.
Recommendations for using your display system performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels. To learn more about LCD technology and missing pixels, consult the dedicated white paper available at www.barcomedical.com. 4. Enhance user comfort Every Barco multi-head display system is color matched with the highest specification in the market. Barco recommends keeping color-matched displays together.
Introduction 23
Introduction (This page intentionally left blank.
Overview Overview Thank you for choosing Barco. Single display or complete system? This manual describes installation and usage of a complete system. A system is a bundling of one or more displays and one or more display controllers (graphics boards). However, if you have purchased the display only instead of a complete system, please refer to the chapters in this manual covering the display, and disregard the information about the display controller.
BarcoMed 5MP2FH Overview BarcoMed 5MP2FH Overview The BarcoMed 5MP2FH Display Controller delivers a quality 2048 x 2560 pixel image with 1024 simultaneous shades of gray for medical imaging applications.
BarcoMed 5MP2FH Overview • Control Panel support for the English (U.S.), Dutch, German, Japanese, Korean, Simplified Chinese and Traditional Chinese languages Supported resolutions for each head of the BarcoMed 5MP2FH display controller • 2048 x 2560 @ 50 HZ (primary) • 2560 x 2048 @ 50 Hz The following resolution is also available on head 1 when the OS is booted in VGA mode.
BarcoMed 5MP2FH Overview longer need to disturb normal radiology activities, as they can be performed while applications are running. I-GUARD® allows radiologists or QA administrators to calibrate their viewing stations or adjust the panel’s curve to DICOM standards without administrator intervention. Power saving The display is equipped with a power saving system. When left idle for a certain time, the computer connected to the display, will power down the display.
BarcoMed 5MP2FH Overview Defect Pixel Compensation (DPC) Current Liquid Crystal Displays contain some missing pixels. These socalled defect pixels can be problematic because you might miss critical information in a mammography image. Barco's Coronis 5MP Mammo flat panel has Defect Pixel Compensation (DPC) technology. DPC detects and identifies the missing pixels in each individual display.
Package contents Package contents Coronis System package Each Coronis system contains one or more display boxes (see below) and a system accessory box containing the following items: • Display controller(s) • CD-ROM with driver and documentation • MediCal QAWeb Agent software • This manual Display box Each display box includes one display and a display accessory box containing the following items: • Plastic cover of the tilt & swivel foot • Power supply • Digital video (DVI) cable (25-pins) • USB cable • T
Parts, controls and connectors Parts, controls and connectors Front 1 BAR CO 3 2 Figure 1 1. Power LED The LED is off when the display is disconnected from the power. The LED is also off when the LED function is disabled in the onscreen display (OSD). The LED is green when the display is on (when enabled in the onscreen menus). The LED is steady orange when the display is in Stand-by powersaving mode.
Parts, controls and connectors It allows to put the display in stand-by, navigate through the onscreen display (OSD) menus and change values in the OSD. Rear 1 A 2 4 8 6 7 5 B 3 4 6 7 5 9 10 Figure 2 1. Connector compartment cover To get access to the connectors, remove the cover by pulling down the 2 clips at the top of the cover. 2. Tilt & swivel foot cover This cover is packed in a separate box when the display is shipped to the customer. 3. Tilt & swivel foot 4. Slot for security cable (e.g.
Parts, controls and connectors When the display is connected to the PC USB bus, you can connect USB devices, such as keyboard, mouse, digital camera, to this connector. 8. Displays with internal power supply only (A): AC power input, 90 - 264 Vac Caution: Double pole / neutral fusing. Connect the power cord, delivered with the display, to this connector. 9. Displays with external power supply only (B): DC power input. Connect the output of the DC power supply delivered with the display to this connector.
Parts, controls and connectors (This page intentionally left blank.
Installation 35
Installation (This page intentionally left blank.
Installation precautions Installation precautions Precautions • Keep your original packaging. It is designed for this display and is the ideal protection during transport. • Avoid reflections in the flat panel to reduce eye strain. • Place the display on a strong and stable table or desk. • Keep the display away from heat sources and provide enough ventilation around the display. • Do not use the display in direct sunlight. • Do not scratch or apply pressure to the LCD panel.
Installing the BarcoMed 5MP2FH display controller Installing the BarcoMed 5MP2FH display controller Caution: Wear a protective ESD strap during installation or handling of the display controller. Electrostatic charges can damage the display controller. Prior to installing your BarcoMed 5MP2FH display controller(s) in your PC please take a few minutes to familiarize yourself with both the display controller and the PCI slots in your computer.
Installing the BarcoMed 5MP2FH display controller Jumper location There is one user settable jumper on the BarcoMed 5MP2F. It is used to enable or disable the VGA capabilites of the display controller. Figure 4: VGA Jumper Enlarged View Using the VGAcapabilities of the BarcoMed 5MP2FH Prior to installing the BarcoMed 5MP2F, decide if you are going to use its on-board VGA capabilities. If you are, check the setting of the Jumper at J-1 on the graphics board.
Installing the BarcoMed 5MP2FH display controller Figure 5: PCI and RAID Controller Slots Install the BarcoMed 5MP2FH controller in your computer following these steps: 1. Turn off the power to your computer and disconnect the power cord, however make sure that the computer chassis is still grounded. 2. Remove the chassis cover according to the manufacturer’s instructions. Be sure to observe safety warnings. 3.
Installing the BarcoMed 5MP2FH display controller 7. Replace the chassis cover, reconnect the power cord, turn on the power, and boot the system as usual. Running multiple BarcoMed 5MP2F display controllers in a single host The physical order of the displays may vary when you are running multiple BarcoMed 5MP2F display controllers. This is due to the PC’s PCI bus control in the system BIOS, and not the BarcoMed display controller.
Display installation Display installation After unpacking the display Important: In the factory, the height-positioning system in the display foot is blocked with a red clip to prevent damage during transportation. Before installing the display, you must remove this clip. Clip Figure 7 To remove the clip: 1. Position the display with its rear side facing you. 2. Pull the red clip out of the fixation holes in the foot. 3. Keep the clip in case the display needs to be shipped later.
Display installation Adjust the panel orientation You can change the orientation of the panel at any time, but it is more convenient to select landscape or portrait orientation before connecting the cables. BAR CO BAR CO Figure 8: Portrait orientation Figure 9: Landscape orientation To change the panel orientation: 1. Stand at the front side of the panel and take the panel at both sides. 2. Very important: Tilt the panel before changing the orientation.
Display installation 3. To change from portrait to landscape, turn the panel counterclockwise. BAR CO Figure 11: To rotate the panel from portrait to landscape 4. To change from landscape to portrait, turn clockwise. Notice: If, after installing the display or the system, you change the panel orientation while an image is on the screen, the result depends on your application: • In a Coronis system, the image orientation will adapt to the new panel orientation automatically after a second.
Display installation Power connection To connect the power: A 1 B 2 Figure 12 1. To get access to the connectors, remove the connector compartment cover by pulling down the 2 clips at the top of the cover. 2. Displays with internal power supply (A): Connect one end of the proper power cable to the AC input (1) of the display. Connect the other end of the power cord to a grounded power outlet. 3.
Display installation 2 3 Figure 13 Video connection Connecting DVI cables: One display: (1) Figure 14 1. Connect one end of the DVI cable to the DVI input of the display. 2. Connect the other end of the DVI cable to the DVI connector of the display controller board. If this board has 2 video heads (2 video outputs), connect to output Vid 1 (Head A). Connecting DVI cables: Two displays: 1.
Display installation USB connection The USB connection allows you to use the display as USB hub, to which you can connect USB devices, such as a keyboard, mouse or digital camera. To connect the USB cable: (1) (2) Figure 15 1. Connect a PC USB downstream connector to the display’s USB upstream connector by means of a USB cable. 2. Connect any USB device to one of the display’s USB downstream connectors.
Display installation • Bind the cables together above and under the foot, by means of the 2 velcro strips attached to the inside of the foot cover (packed inside the accessory box). • At last, put the foot cover back in place. To put the foot cover in place: (1) Figure 16 1. Push the upper side of the cover onto the foot, so that the hooks inside the cover are positioned right under the bulges at the rear of the foot. 2. Slide the cover upward while moving the lower side of the cover towards the foot. 3.
Attaching the display to an arm stand Attaching the display to an arm stand The panel, standard attached to the tilt & swivel foot, is compatible with the VESA 100 mm standard. So it can be used with an arm stand according to the VESA 100 mm standard. Therefore, the tilt & swivel foot must be removed from the panel. Important: • Use an arm that is approved by VESA (according to the VESA 100 mm standard). • Use an arm that can support a weight of at least 13 kg (28.66 lbs).
Attaching the display to an arm stand 5. Lift up the round plastic cover. 6. Remove the four screws fixing the foot while supporting the foot. 7. Attach the arm stand firmly to the panel using 4 screws M4 x 8 mm.
Software Installation Software Installation Tip: These instructions apply to both Windows 2000 and Windows XP. Preparation Prior to installing your Coronis 5MP Mammo software the following should be done. 1. Install the BarcoMed 5MP2FH display controller in your system. 2. Connect the Coronis 5MP Mammo display panel(s) to the BarcoMed 5MP2FH display controller and power supply. 3. Decide if you want to install the Barco DPMS Screen Saver and the Coronis I-Switch Software in addition to the driver. 4.
Software Installation 2. For each BarcoMed 5MP2FH display controller installed in your system Windows will launch the “Found New Hardware Wizard”. Click “Cancel”. Continue to click “Cancel” until Windows stops launching the “Found New Hardware Wizard”. Please be patient as this may take several minutes while Windows scans its library of Plug-and-Play device drivers to see if it has a driver for your BarcoMed 5MP2FH controller. 3.
Software Installation If it determines that the Microsoft Installer is either out of date or missing, it will display the screen shown in figure 20 below. Click “OK” to continue, the wizard will then install a newer version of the Microsoft Installer. Figure 20 The BarcoMed Product Installation Wizard will advise you when it has successfully installed the new version of the Microsoft Installer. Click “OK”. The Wizard may prompt you to restart your system.
Software Installation Figure 21 Driver installation 6. Click “Next” on the Display Driver Wizard’s Welcome Screen to continue or “Cancel” to exit the Display Driver Wizard and return to the Software Install Wizard. The Device Selection Screen’s dialog box should show only those devices physically installed and supported by the BarcoMed display controller driver on your BarcoMed Software CD.
Software Installation Figure 22 Click “OK” to install the new driver. If you don’t want to replace the exiting driver, click “OK” and then click “Cancel”. 7. Your selection on the “Enable DualView” screen determines if DualView is enabled or not. If you wish to enable DualView “check” the checkbox next to “Enable the DualView device?”, and click “Next”. If you do not wish to enable DualView leave the checkbox empty and click “Next” to continue. 8.
Software Installation Figure 23: Windows 2000 Digital Signature Not Found Warning Figure 24: Windows XP Windows Logo Testing Warning 10. When the screen shown in Figure 7 below appears select the palette mode which is the correct one for your viewing application. If you are uncertain use the default settings. You can change the palette mode later (See “Palette Mode” on page 67 of the BarcoMed Driver Tab section). If you want to enable DirectDraw check the checkbox next to “Enable Direct Draw”.
Software Installation Figure 25 When the Driver Install Wizard tells you that it has successfully installed the selected driver, click “Finish”. The wizard will now begin installing the next selected piece of BarcoMed Software. If you are working with the default selections, this will be the Barco DPMS Screen Saver. Please turn to the section, “BARCO DPMS Screen Saver Installation” on page 58.
Software Installation If the Wizard failed to successfully install the selected driver, it will warn you that the installation failed. Click “Finish” to return to the BarcoMed Product Install Wizard. The wizard will now begin installing the next selected piece of BarcoMed Software. Click “Cancel”, then click “Yes” then click “Finish”.
Software Installation Currently the default schemes are not supported in the Japanese, Korean and Chinese languages. We recommend that the users of these three languages install the English default schemes and then rename and save them into their language in the DPMS configuration screen. Click “Next” to continue. 13. The “Ready to Install Program” page will now appear, click “Install” to install DPMS or “Back” if you wish to change any of your DPMS installation settings.
Software Installation 15. Click “Next” on the Welcome Screen of the Coronis 5MP Mammo I-Switch Software InstallShield Wizard to continue the installation. Click “Cancel” to cancel the Coronis 5MP Mammo I-Switch Software installation and return to the BarcoMed Product Install Wizard. 16. The Coronis 5MP Mammo I-Switch Software must be installed on a local hard drive in order for it to function correctly. We recommend that you install it in the default location: C:\WINNT.
Software Installation shown in figure 27 and figure 28 on page 61, click “Yes” or “Continue Anyway” to continue. Figure 27: Windows 2000 Digital Signature Not Found Warning Figure 28: Windows XP Windows Logo Testing Warning The Barco Monitor Plug and Play software will automatically set the resolution for the displays of your Coronis 5MP Mammo System. However, the second head of a dual headed system may be inactive.
Software Installation section “Setting the resolution of your Coronis 5MP Mammo display” on page 126 of the Troubleshooting Section of this manual for instructions on setting the resolution.
Display Controller settings 63
Display Controller settings (This page intentionally left blank.
BarcoMed Driver Tab BarcoMed Driver Tab Introduction After the BarcoMed Windows display controller driver is installed, a new Display Properties tab is available for configuring special features of the BarcoMed display controller. Languages supported The BarcoMed Driver Tab supports the following languages: English (U.
BarcoMed Driver Tab 2. Under Windows 2000 or Windows XP, click on “Settings” tab. Double click on the rectangle that represents the Barco display whose settings you wish to change to bring up its property page. Click on the “BarcoMed Driver” tab ( see figure 29). Figure 29: BarcoMed Driver Tab Status The Status section displays information about the current BarcoMed display controller, driver, and the currently selected display resolution.
BarcoMed Driver Tab Graphics Board This displays the current BarcoMed display controller. Driver Version This displays the current BarcoMed driver version. Resolution This displays the currently selected display resolution. Palette Mode In the Palette Mode section you can choose one of the four following Palette Modes.
BarcoMed Driver Tab grayed-out, and DirectDraw’s access to the hardware will be automatically disabled regardless of whether this check box is checked. DirectDraw is still usable through DirectDraw’s Hardware Emulation Layer. UserModifiable Color Palette This option allows applications to modify the palette contents dynamically.
BarcoMed Driver Tab Figure 31 Please note that dithering is not permitted while in this mode. The Enable Dithering check box will be grayed-out, and dithering will be automatically disabled regardless of whether this check box is checked. This complies with the Windows standard interface method. If you are unsure whether or not your application requires this “Static Gray Palette including Standard System Colors” mode, contact your application provider.
BarcoMed Driver Tab while in this mode. The Enable Dithering check box will be grayed-out, and dithering will be automatically disabled regardless of whether this check box is checked. This complies with the Windows standard interface method. If you are unsure whether or not your application requires this “Static Gray Palette with NO System colors” mode, contact your application provider. Drawing Modes In the Drawing Mode section you can choose from the following Drawing Modes.
BarcoMed Driver Tab note that this option is only available when the User Modifiable Palette Mode is selected. This is because dithering is only supported under Windows when the display is palletized. If either the “Static Gray Palette including Standard System Colors” mode or the “Static Gray Palette with NO System colors” mode is selected, the “Enable Dithering” check box will be grayed-out, and dithering will be automatically disabled regardless of whether this check box is checked.
BarcoMed Driver Tab Disable RGB To Static Gray Color Translation You must have Administrator privileges for this machine to be able to change this option. If you do not have Administrator privileges, this option will be grayed out. Select Disable RGB To Static Gray Color Translation if you wish to have RGB values equally weighted, with 1/3 each.
Barco DPMS Screen Saver Barco DPMS Screen Saver Introduction The BARCO DPMS (Display Power Management Signaling) Screen Saver allows the user to set power and display saving features for medical displays controlled by BarcoMed Display Controllers. At the end of the work day, the display will enter certain DPMS states as requested by the display controller. Note: The Barco DPMS Screen Save will not control any displays connected to a non-Barco display controller.
Barco DPMS Screen Saver BARCO DPMS Screen Saver Options From the “BARCO DPMS Screen Saver Control Panel” you can change many DPMS screen saver elements simultaneously. The DPMS screen saver elements in each scheme are work schedule, work day screen saver, DPMS settings after work day, and many additional options. Current Scheme Lists the three “DEFAULT” schemes which you can use as they are. Or you can modify them to meet your office’s schedule.
Barco DPMS Screen Saver End Work Day The “End Work Day” time is the time after which the system is not expected to be used any more for that day. After the work day, the display is set to one of the DPMS states (Stand-By, Suspend, or Off) by the display controller during user inactivity. Screen Saver During Work Day On LCD based displays, such as the Barco CORONIS displays, it is not necessary to invoke a screen saver as there is no CRT phosphor to preserve.
Barco DPMS Screen Saver Stand-By or Suspend states. If the user wishes to go into the Stand-By or Suspend states before going into the Off state, select the required amount of time for each state. If requested, the display will first go into Stand-By state, then into Suspend state, and then into Off state.
Barco DPMS Screen Saver Use As Logon Screen Saver Check the box to use the BARCO DPMS Screen Saver when no one is logged into the system. Uncheck the box to use the default screen saver when no one is logged into the system. Getting started with the BARCO DPMS Screen Saver The easiest way to get started is to select an existing settings scheme and then modify it with your preferences. Settings schemes are separated into two kinds, DEFAULT (global) and PRIVATE (personal).
Barco DPMS Screen Saver Using the BARCO DPMS Screen Saver Using the Barco DPMS Screen Saver is similar to using any other Windows Screen Saver, each user of the system must select the Barco DPMS Screen Saver so that Windows will store the selection in the user’s profile. If a user does not select the BARCO DPMS Screen Saver as his screen saver, the next time he logs on to the system the screen saver selection may be blank.
Barco DPMS Screen Saver Figure 34: Windows XP Screen Saver Tab 3. Click on the “Settings” button. The “BARCO DPMS Screen Saver Control Panel” will open (see figure 35). Figure 35: BARCO DPMS Settings Control Panel 4. Use the default schemes by selecting one of the three default schemes. Click “OK”. Then Click “OK” again.
Barco DPMS Screen Saver Note: If you make any changes to any of the settings of one of the three default schemes, the Current Scheme field will blank and you MUST SAVE your changes by clicking on the “Save As ...” button. When you click on the “Save As ...” button, the name of the last scheme you used will be automatically displayed, you can then choose to use that scheme name or enter a new name.
Barco DPMS Screen Saver 6. Select the screen saver you wish to use during the work day in the “Screen Saver During Work Day” section. 7. Select the amount of time you wish to spend in the Stand-By and Suspend states after the work day has ended. Please note that after the time specified has elapsed when you are in Stand-By or Suspend, you will automatically go into the Off state. 8. Select the amount of time it takes for your display to warm up.
Barco DPMS Screen Saver Uninstalling BARCO DPMS To remove the BARCO DPMS Screen Saver from your system insert the Coronis 5MP Mammo Software CD in the appropriate device on your computer, run the BarcoMed Product Install Wizard and follow these steps. 1. Select only the DPMS Screen Saver on the BarcoMed Product Install Wizard’s welcome screen and click “Install”. 2. Click “Next” on the Welcome Screen of the BARCO DPMS InstallShield Wizard to begin the installation. 3.
Coronis I-Switch Software Coronis I-Switch Software Overview Note: The CORONIS I-Switch Software is only available for systems which have the Portrait Accelerator in the CORONIS Display Panel and BarcoMed Display Driver releases that include the CORONIS ISwitch Software. The CORONIS I-Switch Software may not be available for your system.
Coronis I-Switch Software controller. If you change the physical orientation of one CORONIS display connected to any given BarcoMed Display Controller, the CORONIS ISwitch Software will change the resolution for both of the CORONIS displays connected to that BarcoMed Display Controller and you will need to change the physical orientation of the second display to match the orientation of the first display.
Barco Display Tab Barco Display Tab Introduction The Barco Display Tab is used for gathering information about the BarcoMed Flat Panel Display(s). To access the Barco Display Tab do the following: 1. Open the “Display Properties Control Panel” by right clicking on the desktop, then select “Properties”. 2. Under Windows® 2000 and Windows® XP, click on the “Settings” tab. Double click on the rectangle that represents the BarcoMed Display you are working with to bring up its properties page.
Barco Display Tab Using the Barco Display Tab Displays All of the available display controllers that are of the same type as the current barco display controller are shown here graphically, with one display icon representing each output of a display controller. The icon orientation reflects the display resolution. Only those outputs with a display attached to them are active. If an icon is grayed out, that indicates a output with no output attached to it.
Barco Display Tab backlight will typically last a very long time, but will only be able to hold a calibrated output of 500 cd/m² for 17000 hours, after which time it will become slowly dimmer. For displays calibrated at 500 cd/ m², an estimate of how long it will be before a backlight replacement is needed = 17000 hours – backlight age. Firmware Revisions: This is the runtime firmware that is loaded in the display. This information may be helpful when there is a problem.
Barco Display Tab (This page intentionally left blank.
Display operation 89
Display operation (This page intentionally left blank.
Display operation Display operation Operating precautions Continuous operation of the display with the same image may result in some image sticking on the LCD panel. Over 10 hours operation with the same image content is not recommended. Switching on DPMS on display and PC and activating a good screen saver may decrease the risk of image sticking (image retention).
Display operation About the On-Screen Display (OSD) About the on-screen display The on-screen display (OSD) has a hierarchical tree structure, with several levels. The top level is the “Main Menu”. MFGD 5621 HD MAIN MENU Luminance Settings Information EXIT Figure 41: Main menu in standard mode The OSD can be used in standard and advanced mode. The OSD appears default in standard mode. For instructions about the advanced mode, please refer to the section “Advanced display operation” on page 97.
Display operation MFGD 5621 HD c MAIN MENU Luminance Settings Information EXIT " SETTINGS DPMS Power LED User controls EXIT On On On 1. Rotate the control wheel 2. Press the control wheel Figure 42: OSD menu navigation 3. To exit from a menu, rotate the control wheel to select EXIT. If you exit from the Main Menu, you exit the OSD. 4. To change an adjustment value (e.g., the luminance value), rotate the control wheel to select the adjustment and press the wheel shortly.
Display operation • switch the display in stand-by mode To disable user controls: 1. Rotate the control wheel to display the on-screen display. The Main Menu appears. 2. Rotate the control wheel to select Settings. 3. Press the control wheel to enter the Settings menu. SETTINGS DPMS Power LED User Controls EXIT On On On Figure 43: Settings menu 4. Rotate the control wheel to select User Controls. 5. Press the control wheel to switch from “On” to “Off”. 6. Exit the menus. To enable user controls: 1.
Display operation 6. Press the control wheel to enter the Settings menu. SETTINGS DPMS Power LED User Controls EXIT On On Off Figure 44: Settings menu 7. Rotate the control wheel to select User Controls. 8. Press the control wheel to switch from “Off” to “On”. 9. Exit the menus. Complete OSD overview Main menu Name Description Luminance Adjust the target luminance to which the display will be stabilized.
Display operation Settings Name Description DPMS Switch on/off the automatic power saving system (DPMS) Power LED Switch the power LED on/off. Note: The LED's orange DPMS state is not influenced by this setting. So, when the display goes into power-saving mode, the LED will turn orange, even if it was switched off by this setting.
Advanced display operation Advanced display operation Introduction Important The functions described in this chapter are intended for trained service staff only! Improper use of these functions may cause the display to not function correctly. Barco cannot be held responsible for the results or damage caused by improper use of these functions. About the Advanced functions The advanced functions are extensions of the standard OSD. By default, a user browsing through the OSD sees only the standard functions.
Advanced display operation Important: Disabling the I-Guard results in an uncalibrated and not stabilized backlight. After switching the power off and on again, the Luminance target and IGuard control are activated again. This is also the case when you control the Luminance function again. Advanced functions in the Settings menu PPU When switched on, the Per Pixel Uniformity system is activated, adjusting the luminance output at pixel level and eliminating screen noise.
Advanced display operation Stabilizer Click to switch the backlight stabilizer on/off Patch Click to hide/display the I-Guard patch. When you hide the patch, the IGuard will not function properly anymore Important: Disabling the I-Guard results in an uncalibrated and not stabilized backlight.
Advanced display operation Firmware The Firmware information menu contains the following items: Name Description Boot Code Version The version of the internal boot code Run Code Version The version of the internal run code CPLD Code Version The version of the internal CPLD code Transpose Version The version of the internal Transpose circuit code Runtimes Runtimes is a submenu from General Information, containing the following items: 100 Name Description Display Lifetime Indicates the total ti
Advanced display operation Measurements Name Description Internal Temperature The temperature measured inside the display Sensor Temperature The internal temperature measured on the I-Guard board FAN speed A value indicating the speed of the fans.
Advanced display operation Name Description Hor.Back Porch: The horizontal back porch of the input signal Hor.Frequency: The horizontal frequency of the input signal Vert.Total: The total number of lines, vertically, of the input signal Vert.Active: The number of active lines, vertically, of the input signal Vert.Blanking: The vertical blanking of the input signal Vert.Front Porch: The vertical front porch of the input signal Vert.Sync: The vertical sync length of the input signal Vert.
Cleaning instructions 103
Cleaning instructions (This page intentionally left blank.
Precautions Precautions Precautions • Take care not to damage or scratch the glass or LCD panel. • Do not apply pressure on the glass or LCD panel. • Do not apply or spray liquid directly to the glass, panel or cabinet as excess liquid may cause damage to internal electronics. Instead, apply the liquid to the cleaning cloth.
Front glass Front glass Proceed as follows: • Clean the glass using a soft cotton cloth, lightly moistened with a watery solution or a mild commercial glass-cleaning product suited for coated glass surfaces. • Wipe dry with a dry cloth.
Cabinet Cabinet Proceed as follows: • Clean the cabinet using a soft cotton cloth, lightly moistened with a recognized cleaning product for medical equipment. • Repeat with water only. • Wipe dry with a dry cloth. • The cabinet has been tested for resistance to the following products: Cidex, Betadine, Alcohol (Isopropyl and Ethyl), Ammonia-based cleaners (Windex) and Aquasonic Gel.
LCD panel LCD panel It may be possible that dust particles have entered the display and are stuck behind the front glass. We recommend to let this cleaning procedure be done in a BARCO service center. The product warranty expires when the user removes the glass panel or otherwise opens the display. However, when really necessary, you can perform the cleaning on site if you can work in dust-free conditions. This is to avoid more dust entering the display when opening it.
LCD panel Figure 46 To clean the LCD panel: • Take care not to touch the I-guard light sensor on the LCD panel. • Dust particles on the LCD panel may be blown away by using a dust remover. E.g., DUST OFF 67 (KONTAKT Chemie). A dust remover is composed of a blend of compressed liquid gases functioning as propellant. They provide a jet of dry inert gas that acts like compressed air for a quick and safe removal of dust particles and other dry contaminants on the surface of the lcd panel or the glass panel.
LCD panel (This page intentionally left blank.
Troubleshooting 111
Troubleshooting (This page intentionally left blank.
General tips General tips • If one display from a multi-head system exhibits problems, try to eliminate the problem by switching video cables or power supplies. In that way you can find out if the problem resides in the display or not.
General tips Problem description Possible tests or solutions Image contains not enough grayscales • You may have installed the driver software with an inappropriate selection of Palette Settings (Static Gray with or without System Colors). Install the driver software again using a different setting for Palette Settings.
General tips Problem description Possible tests or solutions The previous image remains slightly visible on the screen • This phenomenon, called “image sticking” is normal if the same image has been on the screen for a long time. The ghost image will disappear after some time. Over 10 hours operation with the same image content is not recommended. Switching on the display DPMS may decrease the risk of image sticking.
BarcoMed Hardware Tab BarcoMed Hardware Tab Introduction The BarcoMed Hardware Tab is used for gathering information about BarcoMed display controller(s). For all BarcoMed display controller(s) it will display PCI information. For BarcoMed display controller(s) based on the AURA video chipset it will also display information about the Firmware installed on the board.
BarcoMed Hardware Tab Table 2: AURA Controllers Non-AURA Controllers BarcoMed Hardware Tab Support PCI and Firmware Information BarcoMed 3MP2FH BarcoMed 5MP1H PCI Information Only PCI and Firmware Information BarcoMed 5MP1HM BarcoMed 5MP2 BarcoMed 5MP2 AURA BarcoMed Coronis 5MP PCI Information Only PCI and Firmware Information PCI and Firmware Information BarcoMed 5MP2F PCI and Firmware Information BarcoMed 5MP2FH PCI and Firmware Information Using The BarcoMed Hardware Tab To access the BarcoMed
BarcoMed Hardware Tab Figure 47 BarcoMed Hardware Tab under Windows 2000 or Windows XP Device Displays the current BarcoMed display controller, driver, and the currently selected display resolution. Identify Device: This button is for Barco Medical Imaging Systems (MIS) internal use only and is grayed out.
BarcoMed Hardware Tab PCI Information Device ID: Displays the device’s PCI Device ID number. Vendor ID: Displays the device manufacturer’s PCI Vendor ID number. Subsystem ID: Displays the device’s PCI Subsystem ID number. SubsystemVendorID: Displays the device’s PCI Subsystem Vendor ID number. VGA Status: Displays whether the VGA capabilities of the BarcoMed controller are enabled or disabled.
BarcoMed Hardware Tab determine the root cause of a customer problem. It probes the system for various types of system information, and saves it to a web-page report that can then be analyzed by the Barco ImageCare team. BarcoMed Self Exam is implemented in a Wizard Format. The BarcoMed Self Exam Wizard will first ask the user to provide detailed customer contact information.
BarcoMed Hardware Tab Customer Information Screen All fields on this screen must be filled in. This screen asks the user for contact information that will help the Barco support team contact the customer. The user will not be allowed to move forward to the next screen unless all of the fields are filled in. Customer Diagnostic Questions Screen This screen allows the user to tell the Barco ImageCare team as much as possible about the problem.
BarcoMed Hardware Tab information is gathered, the user may not go back in the wizard screens. Completion Screen The BarcoMed Self Exam has collected all of the information. A report called BarcoSelfExam.html with all of the diagnostic data that was collected is created. If a summary report was created, it is called BarcoExamSummary.txt.
BarcoMed Hardware Tab 6. Attach the BarcoMed Self Exam report(s) to the email message and send it. You will receive an acknowledgment of receipt of your email by the end of the next business day.
BarcoMed Hardware Tab Update Device... Button: Clicking this button will launch the BarcoMed Hardware Configuration utility. This program allows the user to flash update the firmware stored in the ROM of the currently selected BarcoMed display controller. The BarcoMed Hardware Configuration utility is implemented in a Wizard format, which guides the user through the flash update procedure. The user will be prompted to select a firmware update file to use for the update process.
Display resolution Display resolution If you are using a color display in conjunction with your Barco grayscale display(s) you should configure your desktop before setting the resolution of the your Barco grayscale display(s).
Display resolution Setting the resolution of your Coronis 5MP Mammo display In order to set the resolution of your Coronis 5MP Mammo display you must be logged in using an account with administrator privileges. 1. To set the resolution of your Coronis 5MP Mammo display(s) right click on the desktop and select “Properties”. 2. Select the “Settings” tab. 3. Select the rectangle that represents the first Coronis 5MP Mammo display attached to the BarcoMed 5MP2FH Display Controller you are working with.
Display resolution Tip: Since Windows 2000 and Windows XP will not let you detach the primary display connected to a particular controller, you may need to temporarily make another display the primary display Caution: if you have a single display configuration and you have enabled DualView, Windows will not allow you to attach the second head. This is normal and not a bug. 4. For the display which is still attached click on the “Advanced” Button. 5.
Display resolution Tip: After installing DualView and setting the resolutions in a Quad-Head Configuration you may need to drag the heads into the proper position in the window on the “Settings” tab, so that the arrangement in the window on the “Settings” tab matches the physical arrangement of your configuration. Figure 48: The Windows Display Properties Control Panel Settings Tab after the drivers have been installed and the resolution set with DualView Enabled.
Driver Re-installation, updates or removal Driver Re-installation, updates or removal Reinstalling or Updating your BarcoMed 5MP2FH Driver Caution: If you previously uninstalled the driver, do not allow Windows’ Plug and Play software to reinstall the driver for you. To reinstall or update only the BarcoMed 5MP2FH Driver, follow the steps described in the section “Using the BarcoMed Product Installation Wizard” with the following changes. 1.
Driver Re-installation, updates or removal Figure 49 3. To update the driver, clear the checkbox next to “DPMS Screen Saver” and “I-Switch” (figure 50) and click “Install”.
Driver Re-installation, updates or removal 4. Please turn to Step 6 on page 54 in the section titled “Driver Installation” and follow the instructions to finish reinstalling or updating your BarcoMed 5MP2FH driver. When the driver has finished installing, click “Finish”. Then click “Finish” again. Reboot the system when prompted and then reset the resolution of your displays if necessary.
Driver Re-installation, updates or removal Figure 51 4. Click “Next”. 5. On the next screen (figure 52), check the checkbox next to “Uninstall this device” and click “Next” to continue. Figure 52 6. Click “Next”. 7. If you installed your driver with DualView enabled, skip to step 8.
Driver Re-installation, updates or removal If you installed your driver with DualView disabled, click “Next” to continue. Then click “Finish” to complete the uninstall process. Click “Finish” again to exit the wizard. Click “Yes” if Windows tells you that “you must restart your computer before the new setting will take effect”. 8. If you have installed your driver in DualView mode the wizard will warn you that you must first disable DualView by rebooting and then run the uninstall program again.
Driver Re-installation, updates or removal (This page intentionally left blank.
Technical Information 135
Technical Information (This page intentionally left blank.
Technical specifications Technical specifications MFGD 5621 HD:: Item Specification Picture panel 21.3-inch Dual Domain IPS Resolution Native: 2560 x 2048 Display area (H x V) 422.4 x 337.92 (mm) Viewing angle (@ 10/1 contrast) Vertical: 170º Horizontal: 170º Pixel Pitch 0.165 mm (H) x 0.
Technical specifications 138 Item Specification Dimensions (W x H x D) In perpendicular vertical position, highest position, tilt = 0°, swivel = 0°: 371 x 444 x 90 mm Net weight 13 kg Operating Temperature 0°C to 40°C, 15°C to 35°C within specs Storage Temperature -20°C to 60°C Humidity 8% - 80% (non-condensing) for operation 5% - 95% (non-condensing) for storage
Connector pin assignments Connector pin assignments DVI connector: 1 8 17 24 16 9 25 Figure 54: DVI connector pin layout Pin no. Signal Pin no.
Glossary Glossary Calibration Each display is calibrated in the factory before it is sent to the customer. After this calibration, black and white luminance are set to the ideal level. A stabilization routine, constantly active when the display is on, keeps these levels constant using the built-in sensor. Display Controller head A display controller (graphics board) converts the digital data from the computer into digital or analog video voltages.
Warranty Statement 141
Warranty Statement (This page intentionally left blank.
Warranty Statement BARCO MID GENERAL WARRANTY TERMS AND CONDITIONS Applicable from Jan 1st 2008 ARTICLE 1: PRODUCT WARRANTY Barco nv, Medical Imaging Division warrants that the equipment will be free of defects in workmanship or material for the warranty period or the specific period of a warranty extension program.
Warranty Statement become the property of Barco nv, MID (or the authorised service centre). 1.5 The repaired equipment shall be returned to the Customer, by regular freight, at Barco nv, MID’s charge. 1.6 Barco nv, MID will replace a product that fails within 90 days after shipment from Barco with a new one, ensuring color matching in the event of a diagnostic multi head display configuration.
Warranty Statement Eg1. • A display is used at 8 hours/day; ie. +/-2.920hours/year • The display system is covered with a warranty period of 5 year • The Guaranteed Backlight Lifetime of that model is 17.000hours. • The Factory Calibrated Luminance cannot be achieved anymore after 4 year, thus corresponding to +/-11.680hours • Result: the backlight replacement is performed under warranty Eg2. • A display is used at 24 hours/day; ie. 8.
Warranty Statement fire, water, thunder or lightning, power failure or fluctuation, disruption of communication lines or due to force majeure, or any reason foreign to the equipment. 2.9 Any specific services or procedures, asked for by Customer, related to verification of repaired equipment. 2.10 The evaluation cost in case of a returned product deemed functional is not covered under warranty and will be charged to the Customer, at Barco’s sole discretion, based on a case-by-case evaluation.
Warranty Statement WHICH SUCH LIABILITY IS BASED. ARTICLE 7: FORCE MAJEURE Either party shall be released from performance of its obligations under this agreement to the extent, and for so long as, the performance of this agreement is impeded by reason of force majeure.
Warranty Statement 148
Warranty Statement 149
Warranty Statement 150
Warranty Statement 151
B4100577-02 July 2008 www.barco.