User`s manual
Table Of Contents
- Preliminary Remarks
- Abbreviated summary
- Design and functions
- Operation
- Controlling
- Menu structure
- Maintenance and servicing
- Technical data
- OverView mDG50-DL
- Overview mDR50-DL
- OverView mDR+50-DL
- OverView cDG67-DL
- OverView cDR67-DL
- OverView cDR+67-DL
- OverView cDG80-DL
- OverView cDR+80-DL
- Electrical data illumination unit 120 W
- Optical data illumination unit 120 W, projection unit XGA resolution
- Optical data illumination unit 120 W, projection unit SXGA resolution
- Optical data illumination unit 120 W, projection unit SXGA+ resolution
- Electrical data illumination unit 100 W
- Optical data illumination unit 100 W, projection unit XGA resolution
- Optical data illumination unit 100 W, projection unit SXGA resolution
- Optical data illumination unit 100 W, projection unit SXGA+ resolution
- Optical data illumination unit 200 W, projection unit XGA resolution
- Use of 3200K filter cartridge
- Operating conditions
- Interfaces
- Scope of delivery
- Consumables
- Spare parts
- Controller
- Addresses
- Trouble shooting
- Configuring notes

7. Maintenance and servicing
Barco - OverView D series - Doc-3353-2 - user's manual - Revision 05 - Aug 2005
________________________________________________________________________
7-11
7.3.3 Illumination unit with 2x120W lamps or 2x100W lamps
The lamp module must be replaced if a fault occurs and if the lamp does not succeed in re-ignition again.
The cooling concept of OverView D requires that the lamp lift is always armed with two
lamps! Do not remove the broken lamp if there is no replacement for it!
With OverView D, lamps are hot swappable and can be replaced while the equipment is on. When opening the
lamp cover, the lamp driver will be disconnected, and there is no risk of electrical shock. However it is NOT rec-
ommended to open the lamp door if the lamp door LED does not show red.
Only open the lamp door when the lamp door LED shines red!
The hot lamp is at high pressure. Do not open the lamp housing before the lamp has
cooled down! Wait at least about 5 minutes after switching off the lamp.
Always hold the lamp by its socket, and never on the glass bulb or reflector! Use fabric
gloves when replacing!
7.3.3.1 Removing the lamp module
• Use a hexagon key size 3 (the key is provided with the system)
• To open the lamp door, a quarter turn counterclockwise will do
• Open the lamp door.
Figure 7-3
opening the lamp door