User`s manual

Table Of Contents
6. Menu structure
Barco - OverView D series - Doc-3353-2 - user's manual - Revision 05 - Aug 2005
________________________________________________________________________
6-17
Figure 6-27
Error sub menu
The properties are checked regularly. In case of a critical status (e.g. lamp door is open, which means that the
cooling cycle cannot operate properly), the checkbox is ticked. If the critical status is solved when checking status
next time, the checkbox is cleared.
Lamp top / Lamp bottom
A lamp error occurs if the active lamp fails during operation and if the ignition of the inactive lamp fails, respec-
tively.
The lamp error bit is set, and the lamp lift can no longer be moved!
This error has to be reset manually.
Press the On/Res. switch for about 6 sec. on the rear of the system to reset the error.
Reset the error
once without doing anything else to make sure that the lamp is really broken
after a lamp exchange
Depending on the operation mode, the behavior of the system differs.
In Hot Standby mode, after resetting the error, the lamp is ignited. If ignition is successful and the lamp has
been switched on, the lift can be moved again. If ignition is a failure, the lamp error is set again and the lift re-
mains locked.