User`s manual

doc-3331-2 OverView cDG67-DL (August 2003) 10-2
10.1 Floor S pace and Maintenance Area
Sufficient floor space and maintenance area must be available when installing O
VERVIEW CDG67-
DL
Floor Space
The floor space must have a sufficient load carrying capacity and be sufficiently flat (according to
DIN 18202). It must not sag by more than 1 millimeter under the load of the
O
VERVIEW CDG67-DL Display Wall. A cement, wood or false floor is permissible.
The load of the O
VERVIEW CDG67-DL is transmitted to the floor via adjustable feet.
No installations (venting ducts, sockets etc.) must be present in the floor in the area of the feet or
of the lower anchoring devices. An area of at least 15 centimeters must be kept free around each
foot. The loading capacity in the area of the feet must be sufficient. Height differences up to
±5 millimeters can be compensated using the adjustable feet.