doc-3331-2 OverView cDG67-DL (August 2003) 7-13
Figure 7-9
inserting the securing ring
Close the lamp door
Use the screw driver and lock the lamp door by turning the screw a quarter turn clockwise.
The lamp door must not be open for more than 15 minutes. If not closed within this
period, the projector will show a warning, and then go to standby after another 5
minutes.
If the operation mode of the projector has been Hot Standby, the new lamp is immediately
switched on.
In case the operation mode has been
Cold Standby or Auto switch, the lamp will be switched on
automatically in case it becomes the active lamp (i.e. in case of a lamp failure of the other lamp or
after the switch cycle.
After the replacement of a lamp module, the new serial number has to be entered,
and it is highly recommended to select the lamp optimization procedure, cf.
Reset
runtime
, Lamp Optimization.
In emergency cases the lamp optimization procedure can be skipped for the moment
and carried out later.