User`s manual

doc-3331-2 OverView cDG67-DL (August 2003) 7-10
7.3.3 Removi ng a Lamp
The lamp module must be replaced if a fault occurs.
The cooling concept of OverView D requires that the lamp lift is always armed with
two lamps! Do not remove the broken lamp if there is no replacement for it!
With OverView cDG67-DL, lamps are hot swappable and can be replaced while the equipment is
on. When opening the lamp cover, the lamp driver will be disconnected, and there is no risk of
electrical shock. However it is NOT recommended to open the lamp door if the lamp door LED
does not show red.
Only open the lamp door when the lamp door LED shines red!
The hot lamp is at high pressure. Do not open the lamp housing before the lamp
has cooled down! Wait at least about 5 minutes after switching off the lamp.
Always hold the lamp by its socket, and never on the glass bulb or reflector! Use
fabric gloves when replacing!
Use a screwdriver with a blade of 1mm thickness.
To open the lamp door, a quarter turn counterclockwise will do
Open the lamp door.
Figure 7-3
opening the lamp door