User`s manual
doc-3331-2 OverView cDG67-DL (August 2003) 7-3
7.1.3 Active L amp Selection Switch
The Active Lamp Selection Switch [3] has 3 positions: neutral (not pushed), up (pushed to the
top), down (pushed to the bottom).
The switch is slope sensitive and reacts when changing from one position to the other. To prevent
operation errors, a minimum time is required for pushing. After sending a command (after pushing
the switch), the next command can only be sent after the release of the switch for at lease 0.5s.
In case the power switch [1] is off, there is no reaction.
Projector
status
Power LED Action Function
Up Lamp Top becomes active,
lift is going down
Standby
(no error)
red, static
Down Lamp bottom becomes active,
lift is going up
Up Toggling between the status level modes
(for servicing only)
Standby
(no error)
Standby switch
pushed down
red, static
Down Toggling between the status level modes
(for servicing only)
Up no functionStandby
(error)
red,
blinking fast
Down no function
Up Lamp Top becomes active,
lift is going down
On
(no error)
green, static
Down Lamp bottom becomes active,
lift is going up
Up Toggling between the status level modes
(for servicing only)
On
(no error)
Standby switch
pushed up
green, static
Down Toggling between the status level modes
(for servicing only)
Up no functionOn
(error)
green,
blinking slowly
down no function
Up no functionProjector is
starting up or
shutting down
blinking yellow
Down no function