Operator`s manual
Manual # 26-0206000-00 / Revision A BlendPRO – Wide Screen Image Processor 63
Description: Adjusts the Input Clocks Per Line of the current source. When the op is A (automatic configuration),
the input is automatically configured and sized to fit within the output format.
Parameters: in - input [1-4]
op - Mode; [A|M|I] Automatic Configuration|Manual|Increment
nnnn - Clocks per Line value; [0 - 4096]
Query:
ICPLBP? in
Returns the Input Clocks Per Line of the current source in the format:
=nnnn
Example: ICPLBP 1 M 100 (Manually adjusts the Input clock per line to 100 on input 1.)
ICPLBP 2 A (Automatically position and size input configuration on input 2.)
ICPLBP? 4 (Returns the Input clock per line of input 4.)
Command:
ICRECBP in
Description: Recalls from non-volatile memory the input configuration of the selected input and loads it. If the
Selected input does not have a stored input configuration, the default configuration is recalled and
loaded.
Parameters: in – Input number; [1..4]
Example: ICRECBP 4 (Recalls and loads the input configuration stored for input 4.)
Command:
ICRSTBP in
Description: Resets the input configuration of the current source.
Parameters: in - input [1-4]
Example: ICRSTBP 1 (Resets the input configuration for the current source on input 1.)
Command:
ICSAVBP in
Description: Saves the configuration to non-volatile memory.
Parameters: in - input [1-4]
Example: ICSAVBP 1 (Saves input configuration in non-volatile memory for input 1.)
Command:
IDBP num
Description: Sets RS-485 Serial ID number for the BlendPRO.
Parameters: num - ID number; [1-32]
Query:
IDBP?
Returns the RS-485 Serial ID number:
=num
Example: IDBP 1 (Sets RS-485 Serial ID to 1.)
IDBP? (Returns RS-485 Serial ID.)
Command:
IRSPBP in op pos nnn
Description: Adjusts the Input Raster Position of the specified source. Horizontal position can be adjusted --128
to 128 from the base Horizontal position value. Vertical position can be adjusted -16 to 16 from the
base Vertical value.
Parameters: in - input [1-4]
op – Update Mode; [I|M], Increment|Manual
pos - Select Raster Control; [H|V], Horizontal Pos|Vertical Pos
nnn - Increment/Decrement value: H[-128 – 128], V[-16 – 16] from base.
Query:
IRSPBP? s
Returns the Input Raster Position of the specified source
=Hcur Hbase Vcur Vbase
where Hcur = Current Input Raster Horizontal Position value. Value can be –32 to 32 of Horiz Base