62 BlendPRO – Wide Screen Image Processor Manual # 26-0206000-00 / Revision A
Parameters: en - Mode; [0|1], Disable|Enable
exp - Gamma; [1.0-5.0]
Query:
EFTB?
Returns the Edge Feather Basic Mode LUT value.
=en exp
Example: EFTB 1 1.0 (Enables edge blending with a gamma of 1.0.)
EFTB? (Returns edge blending mode and gamma settings.)
Command:
HELP [op]
Description: Displays the list of available command on a terminal emulator
Parameters: [op] - Optional parameter to list only commands starting with op [A-Z]
Example: HELP (Returns the command list.)
HELP D (Returns commands starting with D.)
Command:
IBRTBP in op nnn.n
Description: Adjusts the Input Brightness value of the current source.
Parameters: in - input [1-4]
op - Select Brightness Control; [C|R|G|B], Common|Red|Green|Blue
nnn.n - Brightness value; C Range 75 to 125%, RGB Range -25 to 25%
Query:
IBRTBP? in
Returns the Input Brightness of the Common, Red, Green, and Blue of the current source in the format:
=ccc.c rr.r gg.g bb.b
Example: IBRTBP 1 C 110 (Adjusts input 1 Input Brightness for the current source to be 110%.)
IBRTBP? 2 (Returns input 2 Input Brightness for Common, Red, Green, and Blue.)
Command:
ICNTBP in op nnn.n
Description: Adjusts the Input Contrast values of the current source.
Parameters: in - input [1-4]
op - Select Contrast Control; [C|R|G|B], Common|Red|Green|Blue
nnn.n - Contrast value; C Range 75 - 125%, RGB Range -25 - 25%
Query:
ICNTBP? in
Returns the Input Contrast of the Common, Red, Green, and Blue of the current source in the format:
=ccc.c rr.r gg.g bb.b
Example: ICNTBP 1 C 100 (Adjusts the Common Input Contrast value as 100% on input 1.)
ICNTBP? 3 (Returns the input Contrast for Common, Red, Green and Blue of input 3.)
Command:
ICPHOBP in op nn
Description: Adjusts the Input Clock Phase Offset of the current source.
Parameters: in - input [1-4]
op - Operation; [A|M|I], Auto Config|Manual|Increment
nn - Phase value; [-16 - 15]
Query:
ICPHOBP? in
Returns the Input Clock Phase Offset of the current source in the format:
=nn
Example: ICPHOBP 1 M 15 (Adjusts the Input clock phase offset manually to 15 on input 1.)
ICPHOBP? 2 (Returns the Input clock phase offset of input 2.)
Command:
ICPLBP in op nnnn