Instruction manual
76 ScreenPRO-II Controller • User’s Guide
3. Hardware Installation
System Installation
12. Power Connection
a.
Connect an AC power cord to the AC Power Connector on the rear of
each ScreenPRO-II chassis, and then to AC outlets.
b. Connect an AC power cord to the AC Power Connector on the rear of
the ScreenPRO-II Controller chassis, and then to an AC outlet.
c. Per your system configuration, connect AC Power cords to MatrixPRO
routers and BlendPRO-II, and then to AC outlets.
d. Connect AC Power cords (or AC adapters) to all peripheral equipment,
such as Ethernet Hubs and monitors.
Please note:
~ Connect each unit only to a properly rated supply circuit.
~ Reliable grounding of rack-mounted equipment should be maintained.
13. Tally Connection — If you are using the optional Tally board, connect tally “relay
closure” lines from the ScreenPRO-II Controller’s
Tally connector to the desired
external devices (such as cameras). Eight tally circuits are provided. In
Appendix A, refer to the “
Tally Connector” section on page 262 for pinout details
14. Power On — turn on power to all units.
15. System ID — required for use with the ScreenPRO-II Controller. On each
ScreenPRO-II chassis:
a. Access the Remote Control Menu by pressing {REMOTE CONTROL}
on the
Home Menu. This menu enables you to set the ID of the
ScreenPRO-II chassis.
b. Set the ScreenPRO-II chassis ID to a unique value that is not used by
another chassis. The system will not function if duplicate IDs are in use.
16. Display Calibration — calibrate the ScreenPRO-II Controller’s Touch Screen
display using the
Display Settings Menu. From the Home Menu, press
{
DISPLAY} > {LCD CAL}, and following the prompts to calibrate the display.
If you are using BlendPRO-II, please review the “
Overview of Edge-Blending
Technology” section on page 79.
pÅêÉÉåmolJff=dÉåäçÅâ=qÉêãáå~íáçå
On the rear of each ScreenPRO-II chassis, one recessed Termination Switch is provided
for genlock termination (adjacent to the
Genlock Loop connector).
• Terminated — when the switch is pushed in, the connection is terminated (75
Ohms).
• Un-terminated — when the switch is out, the connection is un-terminated.
If a particular ScreenPRO-II chassis is the last device in a reference video chain, ensure
that the
Termination Switch is pushed in. If a particular ScreenPRO-II chassis is in the
middle of a reference chain, ensure that the
Termination Switch is out.
Note
The ScreenPRO-II Controller will detect duplicate IDs and
prompt the user to correct the problem. Only the first device
will connect to the console. Other devices with conflicting IDs