User's Manual
2. Xenon bulb lamp replacement process
2.2 Removal of the xenon bulb lamp
WARNING: DO NOT PERMIT UNAUTHORIZED PERSONNEL TO PERFORM OR ATTEMPT ANY PHASE O F
XENON BULB LAMP HA NDLING OR SERVICE.
WARNING: This procedure may only be performed by qualified technical service personnel.
CAUTION: Xenon comp act arc lamps are highly pressurized. Wh en ignited, the norm al operating temperature
of the bulb increases the pressure to a level at which the bulb may explode if not handled in strict accord ance
to the m anufacturer’s instructions. The bulb is stable at room temperature, but m ay still explode if dro pped
or o therwise mishandled. W henever the lamp h ouse, containing a xenon bulb lamp, has to be dismantled or
whenever the protective container or cloth has to be removed from the xenon bulb lamp, authorized protective
clothing MUST be worn!
WARNING: Always wear face protection (full face shield with neck protector) when handling xenon bulb
lamps.
WARNING: Alwa ys wear protective clothing (welder’s jacket) w hen handling xenon bulb lam ps.
WARNING: Always wear clean leather gloves w ith w rist protectors when handling xen on bulb lamps.
Necessary tools
• 4 mm Allen wrench.
• 17 mm open e nded spanner (2 pieces).
How to remove the xenon lamp bulb from the lamp house?
1. Ensure that you wear protective clothing, a full face shield and protective gloves.
2. Remove first the lamps house side cover and then the lamp house UV blocker a ssembly by releasing the retaining thumbscrews
as illustrated. Support the xenon bulb lamp while removing the UV blocke r assembly.
12
Image 2-3
10 R59770175 XENON BULB LAMP REPLACEMENT 24/09/2008