user manual
Home
 > 
5. Power and Data Distribution
 > 
5.5 PDB
-
5 Input & Output
5.5 PDB
-
5 Input & Output 
Connections Checklist 
●
DVI over HDMI or SDI (to a R1i only) signal connected to Vizomo capture card
● 100-240 50/60 VAC power to Vizomo 
●
PXL data cable from a Vizomo to the PXL Data Input jack on the back of the PDB
-5. 
● Power and data cable(s) from the fixture(s) to the appropriate PXL Cable output(s) on the back of the PDB-5. 
● PowerCon end of the PDB5 power cable to the AC Power Input A jack on the back of the PDB-5. 
●
IEC end of the PDB5 power cable to a 200
-240 VAC power source. 
Power Inputs A & B 
The PDB
-5 has two power 16A inputs on the rear panel labeled A and B. 
Input A must always be used as it powers the electronics inside the PDB-5. 
If only input A is used then all outputs (1 through 6) will be powered by input A. 
When input B is used in addition to A, then outputs 4, 5, and 6 automatically switch over and become powered by input B. This doubles the PDB-5's total 
capacity. 
A green indicator on the front panel shows when input B is being used. 
PXL Cable Outputs 
The PDB
-5 has 6x 10 amp outputs with breakers for AC power distribution. 
The limit for each PDB
-
5 output is 10 A, with a total output of 32 A maximum per PDB
-5, if both inputs A and B are used. 
The maximum number of C8v tiles per PDB
-5 port is 25 (this is limited by data, not power). 
The maximum number of C11 tiles per PDB
-5 port is 16 (this is limited by data, not power). 
For additional information on the PXL Cable, see "
Cables & Connectors
" in the C
-
series Tile Manual.
108 . 5. Power and Data Distribution