5. Power and Data Distribution
 > 
5.1 Hookup with a PXL Switch 
5.1 Hookup with a PXL Switch 
The image below illustrates the data flow of a C-series system from image capture to tile using a PXL switch for data and power routing.  
Connections Checklist 
●
DVI over HDMI or SDI (to a R1i only) signal connected to Vizomo capture card
● Network cable from a Vizomo PXL output to a switch PXL input 
●
Break
-
in cable from switch PXL output to tiles. Observe maximum tiles per line limit
● 100-240V 50/60Hz VAC power source to Vizomo and PXL Switch(es) 
● 200-240V 50/60Hz VAC power source to PXL tiles 
Observe the following data limits when setting up your C-series display. 
WARNING
• Never attach more than one PXL switch to a Vizomo output.  
• Never attach more than one Vizomo PXL output to a switch.  
Fixture  
Max panels per PDB
-5 output  
C7 
 8 
 C11
 16
 C8v
 25
5. Power and Data Distribution . 101
PXL System