Instruction manual
104 ACS-2048 • User’s Guide
_K==oÉãçíÉ=`çåíêçä=mêçíçÅçä
Remote Commands
^rqlp^sb=
• Description: Auto Input Settings Save
• Command Format: AUTOSAVE -m (mode)
• Parameters: -m (mode): 0 - off, 1 - on (default: off)
• Query Format: AUTOSAVE -?
• Query Response: AUTOSAVE -m (mode) --min 0 -- max 1
pbijlab=
• Description: Sets whether input selection of inputs w/o valid syncs will be made.
• Command Format: SELMODE -m (mode)
• Parameters: -m (mode): 0 - don't allow selection, 1 - allow selection (Default: off)
• Query Format: SELMODE -?
• Query Response: SELMODE -m (mode) --min 0 -- max 1
`lkqbuq=
• Description: Sets menu context
• Command Format: CONTEXT -m (mode)
• Parameters: -m (mode): 0 - off, 1 - on
• Query Format: CONTEXT -?
• Query Response: CONTEXT -m (mode) --min 0 -- max 1
qbjm
• Description: Query only command for the temperature of the unit.
• Query Format: TEMP -?
• Query Response: TEMP -c (celsius) -f (fahrenheit)
obpbq
• Description: Reset unit
• Command Format: RESET [-f | -s ]
• Parameters:
-f : factory reset
Or
-s: soft reset
• Query Format: N/A
• Query Response: N/A
sbo
• Description: Display Version info
• Command Format: VER