Table-4 MP-4xxx Series Model Chart.
Table-5 Actuator Part Numbers that are Compliant with CE
Actuator
Part
Number
Internal
Wiring
(See
Figure)
Input Control Signal External Wiring (and required Interface Module that must be purchased separately)
(See Figure)
Power
Requirements
Output Shaft
Aux.
Switch
Built-in
Trans-
former
b
2-Position
SPST
Spring
Return
2-Position
or
Floating
SPDT
Barber-Colman Microtherm
a
(Proportional Electric)
135 to
1,000 Ω
Slidewire
Voltage Vdc
Current
mAdc
Volts Hz. Amps
Torque
Lb.-in.
(N-m)
Timing
Seconds
(No Load)
Degrees of
Rotation
Spring
Return
Standard
Sequencing
of Two
Actuators
5-Position
(Adj. Min
Position)
MP5-4651 Figure-26 Figure-4 Figure-6 – – –
Figure-15
(AE-504)
Figure-18
(CP-8301-240)
Figure-21
c
or
Figure-23
d
240 50 0.25 50 (5.6) 108 180 (Adj.
f
)CWSPDTYes
MP-4701 Figure-31 – – – – Figure-13 – – – 240 60 0.25 50 (5.6) 90 180 (non-Adj.) CCW None Yes
MP5-4751 Figure-26 Figure-4 Figure-6 – – –
Figure-15
(AE-504)
Figure-18
(CP-8301-240)
Figure-21
c
or
Figure-23
d
240 50 0.25 50 (5.6) 108 180 (non-Adj.) CCW SPDT Yes
MP-4851 Figure-26 – Figure-6 – – –
Figure-15
(AE-504)
Figure-18
(CP-8301-240)
Figure-21
c
or
Figure-23
d
240 60 0.25 220 (24.9) 130 180 (Adj.
f
)NoSPDTYes
MP5-4851 Figure-26 – Figure-6 – – –
Figure-15
(AE-504)
Figure-18
(CP-8301-240)
Figure-21
c
or
Figure-23
d
240 50 0.25 220 (24.9) 156 180 (Adj.
f
)NoSPDTYes
a Typical Barber-Colman Microtherm Controllers: PP-22x Series; TP-1xx Series; TP-4xx Series; TP-101x Series; TP-103x Series; and TP-1xxxx Series.
b Units with a “-2-x” suffix, e.g. MP-xxxx-xxx-2-x, include a built-in transformer (used for Barber-Colman Microtherm or with AE-504) with secondary leads wired externally to terminals 7 and 8 of the actuator. Red (24 Vac) to
terminal 8 and Blue (12 Vac) to terminal 7. When these actuators are used with controllers other than Barber-Colman Microtherm or AE-504, disconnect the Red and Blue leads and tape off. Note: Models prior to “-2-x” suffix had
transformer wired directly to potentiometer. To disconnect the transformer, remove the back plate of the actuator, disconnect and tape the transformer leads.
c Requires CP-8391-910.
d Requires CP-8391-716.
e Rotation adjustable 45 to 320°. Caution: On actuators with proportional input signals changing the rotation will affect the control, since the internal feedback potentiometer’s travel is fixed.
f Integral solid state drive accepts 2-15 Vdc voltage.
g MP-495 is not rated for UL or CSA
MP-361-0-0-2
MP-363-0-0-2
MP-367-0-0-2
MP-371-0-0-2
MP-377-0-0-2
MP-379-0-0-2
MP-381-0-0-2
MP-382-0-0-2
MP-383-0-0-2
MP-387-0-0-2
MP-389-0-0-2
MP-481-600-0-2
MP-481-691-0-2
MP-481-692-0-2