User Guide

Table Of Contents
10 © Copyright 2007 TAC All Rights Reserved. F-15479-8
TYPICAL APPLICATIONS (wiring diagrams)
List of Figures
Figure-3 External Wiring for SPST Control of MP-361 and MP-371, 24 Vac
Actuators.
page 11
Figure-4 External Wiring for SPST Control of MP-465, MP-475, MP5-4651, and
MP5-4751 Line Voltage Actuators.
page 11
Figure-5 External Wiring for SPDT (Snap Acting or Floating) Switch for Control of
24 Vac Actuators MP-361, MP-371, MP-381, MP-382 and MP-2113-500.
page 12
Figure-6 External Wiring for SPDT (Snap Acting or Floating) Switch for Control of
Line Voltage Actuators.
page 12
Figure-7 TAC Microtherm Controller with 24 Vac Actuators – Standard Wiring
Diagram.
Page 13
Figure-8 TAC Microtherm Controller with 24 Vac Actuators – Reversed (Cooling)
Wiring Diagram.
page 13
Figure-9 External Wiring of TAC Microtherm Controller with Line Voltage Actuator
– Standard Wiring.
page 14
Figure-10 External Wiring of TAC Microtherm Controller with Line Voltage Actuator
– Reversed (Cooling) Wiring.
page 14
Figure-11 External Wiring for TAC Microtherm Controller with 24 Vac Sequencing
Actuators.
page 15
Figure-12 External Wiring for TAC Microtherm Controller with Five-Position 24 Vac
Actuators.
page 16
Figure-13 External Wiring for TAC Microtherm Controller with Five-Position Line
Voltage Actuator.
page 17
Figure-14 External Wiring for Slidewire Controller with 24 Vac Actuators. page 18
Figure-15 External Wiring for Slidewire Controller with Line Voltage Actuator. page 18
Figure-16 External Wiring for CP-8301-120, Vdc Interface with Line Voltage
Actuators without Internal Transformer.
page 19
Figure-17 External Wiring for CP-8301-024, Vdc Interface with 24 Vac Actuators. page 20
Figure-18 External Wiring for CP-8301-120 and CP-8301-240, Vdc Interface with
Line Voltage Actuators with Internal Transformer.
page 21
Figure-19 External Wiring for CP-8391-913, 4 to 20 mAdc Interface with 24 Vac
Actuators.
page 22
Figure-20 External Wiring for CP-8391-910, 4 to 20 mAdc Interface with Line
Voltage Actuators without Internal Transformer.
page 22
Figure-21 External Wiring for CP-8391-910 and CP-8391-911, 4 to 20 mAdc
Interface with Line Voltage Actuators with Internal Transformer.
page 23
Figure-22 External Wiring for CP-8391-716, mAdc Interface with Line Voltage
Actuators without Internal Transformer.
page 23
Figure-23 External Wiring for CP-8391-716, mAdc Interface with Line Voltage
Actuators with Internal Transformer.
page 24
Figure-24 Internal Wiring for 24 Vac Actuator. page 24
Figure-25 Internal Wiring for Line Voltage Actuators. page 25
Figure-26 Internal Wiring for Line Voltage Actuator with Built-in Transformer. page 25
Figure-27 Internal Wiring for 24 Vac Actuator without Limit Switches (Actuator is
Stall Type with Built-in Mechanical Stops).
page 26
Figure-28 Internal Wiring for Line Voltage Actuators without Limit Switches
(Actuator is Stall Type with Built-in Mechanical Stops.)
page 26
Figure-29 Internal Wiring for Line Voltage Actuators without Limit Switches and
Built-in Transformer (Actuator is Stall Type with Built-in Mechanical
Stops).
page 27
Figure-30 Internal Wiring for 24 Vac Five-Position Actuators. page 27
Figure-31 Internal Wiring for LIne Voltage Five-Position Actuators. page 28
Figure-32 Internal Wiring for 24 Vac Sequencing Actuators. page 28