Product Overview
Table Of Contents
- Application
 - Features
 - Applicable Literature
 - SPECIFICATIONS
 - ACCESSORIES
 - TYPICAL APPLICATIONS (wiring diagrams)
- List of Figures
- Typical Actuators: MP-361, MP-371, MP-381, MP-382, and MP-2113-500.
 - Typical Actuators: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-4553, MP-454, MP-465, MP-483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-2151-500, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical Actuators: MP-361, MP-371, MP-381, MP-382, and MP-2113-500.
 - Typical TAC Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Cooling TAC Microtherm: TP-1031.
 - Typical TAC Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Actuators: MP-465, MP-475, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-2151-500, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical TAC Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Cooling TAC Microtherm: TP-1031.
 - Typical Actuators: MP-465, MP-475, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-2151-500, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical TAC Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Actuators: MP-367, MP-377, and MP-387.
 - Typical TAC Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Sequence of Operation
 - Typical TAC Microtherm Controllers: TP-2xx Series, TP-3xx Series, and TP-4xx Series.
 - Cycle of Operation
 - Typical TAC Microtherm Controllers: TP-2xx Series, TP-3xx Series, and TP-4xx Series.
 - Cycle of Operation
 - Typical Actuators which require AE-504 purchased separately: MP-361, MP-371, MP-382, and MP-2113-500.
 - Typical Actuators which require AE-504 purchased separately: MP-465, MP-475, MP-483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-4651, MP5-4751, MP-4851, MP5-4851.
 - Typical Actuators which require CP-8301-120 purchased separately: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-454.
 - Typical Actuators with CP-8301-120 factory installed and wired: MP-461-600, MP-471-600, MP-481-600, MP-2110-601.
 - Typical Actuators which require CP-8301-024 purchased separately: MP-361, MP-371, MP-381, MP-382, MP-2113-500.
 - Typical Actuators which require CP-8301-120 purchased separately: MP-465, MP-475, MP-483, MP-485, MP-486, MP495, MP-2130-500, MP-2150-500.
 - Typical Actuators which require CP-8301-240 purchased separately: MP5-2151-500, MP5-4651, MP5-4751, MP-4851, MP5-4851.
 - Typical Actuators which require CP-8391-913 purchased separately: MP-361, MP-371, MP-381, MP-382, MP-2113-500.
 - Typical Actuators which require CP-8391-910 purchased separately: MP-421, MP-422, MP-424, MP-451, MP-452, MP-453, MP-454.
 - Typical Actuators which require CP-8391-910 purchased separately: MP-465, MP-475, MP483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500.
 - Typical Actuators which require CP-8391-716 purchased separately: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-453, MP-454.
 - Typical 120 Vac Actuators which require CP-8391-716 purchased separately: MP-465, MP-475. MP-483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500.
 - Typical 240 Vac Actuators which require CP-8391-716 purchased separately: MP5-2151-500, MP5-4651, MP5-4751, MP-4851, MP5-4851.
 - Typical Actuators: MP-361, MP-371, MP-381, and MP-382.
 - Typical Actuators: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-453, MP-454, MP-461-600, MP-471-600, and MP-481-600.
 - Typical Actuators: MP-465, MP-475, MP-483, MP-486, MP-495, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical Actuator: MP-2113-500.
 - Typical Actuator: MP-2110-600.
 - Typical Actuators: MP-2130-500, MP-2150-500, MP5-2151-500.
 - Typical Actuators: MP-379 and MP-389
 - Typical Actuators: MP-470, MP-480, and MP-4701.
 - Typical Actuators: MP-367, MP-377, and MP-387.
 
 
 - List of Figures
 - INSTALLATION
 - MOUNTING
 - WIRING
 - ADJUSTMENTS
 - CHECKOUT
- GO, NO GO Test
- Slidewire Controller with 24 Vac Actuators
 - Slidewire Controller with Line Voltage Actuator
 - CP-8301-120, Vdc Interface (TAC System 8000) with Line Voltage Actuators without Internal Transformer
 - CP-8301-024, Vdc Interface (TAC System 8000) with 24 Vac Actuators
 - CP-8301-120 and CP-8301-240, Vdc Interface (TAC System 8000) with Line Voltage Actuators with Internal Transformer
 - CP-8391-xxx Series mAdc Interface
 
 - Positioning the Actuator with the Controller
 
 - GO, NO GO Test
 - REPLACEMENT PARTS
 - MAINTENANCE
 - TROUBLESHOOTING
 - REPAIR
 - DIMENSIONAL DATA
 
F-15479-8 © Copyright 2007 TAC All Rights Reserved. 9
ACCESSORIES
Damper linkage accessories
AM-111 Crank arm for 5/16" (7.9 mm) diameter damper shaft
AM-112 Crank arm for 3/8" (9.5 mm) diameter damper shaft
AM-113 Crank arm for actuator or 1/2" (12.7 mm) diameter damper shaft
AM-115 Crank arm for 7/16" (11.1 mm) diameter damper shaft
AM-116 Splined crank arm for actuator
AM-122 Linkage connector, straight type
AM-123 Damper clip
AM-125 5/16" x 20" (7.9 mm x 0.5 m) damper rod
AM-125-048 5/16" x 48" (7.9 mm x 1.2 m) damper rod
AM-132 Ball joint connector
AM-161 Damper linkage kit
AM-161-1 Damper linkage kit
AM-301 90 degree mounting bracket
Miscellaneous actuator accessories
AM-321 Two step switch kit
AM-332 Potentiometer kit
AM-341 Four step switch kit
AM-342 Two step switch and potentiometer kit
AM-363 NEMA 4 gasket kit for non-spring return actuators only
AM-402 Hazardous location housing for spring return units except suffix “-600”
TOOL-201 Calibration kit for TAC System 8000
TM
TOOL-209 135 Ω slidewire calibration kit
Valve linkage for 50 lb.-in. minimum, 180° actuator
AV-329 Valve linkage for 2-1/2" and 3" VB-9323
AV-391 Valve linkage for 15 to 50 mm and 1/2" to 2” VB-72xx or VB-73xx (also valve 
linkage for obsolete 1/2” to 1-1/4" VB-92xx or VB-93xx)
AV-392 Valve linkage for obsolete 1-1/2" and 2" VB-92xx or VB-93xx
AV-395 Valve linkage for 65 and 80 mm VB-9215 or VB-9315, and 2-1/2" to 4" VB-9213 or 
VB-9313
Valve linkage for 130 lb.-in. minimum, 180° actuator
AV-330 Valve linkage for 2-1/2" and 3" VB-9323
AV-352 Valve linkage for 2-1/2" to 6" VB-921x or VB-931x, 4" to 6" VB-9323
AV-393 Valve linkage for 15 to 50 mm and 1/2” to 2” VB-72xx or VB-73xx (also valve 
linkage for obsolete 1/2" to 1-1/4" VB-92xx or VB-93xx)
AV-394 Valve linkage for obsolete 1-1/2" and 2" VB-92xx or VB-93xx
AV-396 Valve linkage for 65 and 80 mm VB-9215 or VB-9315, and 2-1/2" to 4" VB-921x or 
VB-931x
Valve Linkage for 50 lb.-in. MP6-xxx and MP7-xxx Hazardous Location Actuators
AV-291  Valve linkage for ½ to 2" VB-7xxx valves assembled with hazardous location 
actuator assemblies.
AV-295  Valve linkage for 2½ to 3" VB-9xxx valves assembled with hazardous location 
actuator assemblies.
Valve Linkage for 220 lb.-in. MP6-xxx and MP7-xxx Hazardous Location Actuators
AV-293  Valve linkage for ½ to 2" VB-7xxx valves assembled with hazardous location 
actuator assemblies
AV-296  Valve linkage for 2½ to 3" VB-9xxx valves assembled with hazardous location 
actuator assemblies