Product Overview
Table Of Contents
- Application
 - Features
 - Applicable Literature
 - SPECIFICATIONS
 - ACCESSORIES
 - TYPICAL APPLICATIONS (wiring diagrams)
- List of Figures
- Typical Actuators: MP-361, MP-371, MP-381, MP-382, and MP-2113-500.
 - Typical Actuators: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-4553, MP-454, MP-465, MP-483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-2151-500, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical Actuators: MP-361, MP-371, MP-381, MP-382, and MP-2113-500.
 - Typical Schneider Electric Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Cooling Schneider Electric Microtherm: TP-1031.
 - Typical Schneider Electric Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Actuators: MP-465, MP-475, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-2151-500, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical Schneider Electric Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Cooling Schneider Electric Microtherm: TP-1031.
 - Typical Actuators: MP-465, MP-475, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-2151-500, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical Schneider Electric Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Typical Actuators: MP-367, MP-377, and MP-387.
 - Typical Schneider Electric Microtherm Controllers: PP-22x Series, TP-2xx Series, TP-3xx Series, TP-4xx Series, and TP-101x Series.
 - Sequence of Operation
 - Typical Schneider Electric Microtherm Controllers: TP-2xx Series, TP-3xx Series, and TP-4xx Series.
 - Cycle of Operation
 - Typical Schneider Electric Microtherm Controllers: TP-2xx Series, TP-3xx Series, and TP-4xx Series.
 - Cycle of Operation
 - Typical Actuators which require AE-504 purchased separately: MP-361, MP-371, MP-382, and MP-2113-500.
 - Typical Actuators which require AE-504 purchased separately: MP-465, MP-475, MP-483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500, MP5-4651, MP5-4751, MP-4851, MP5-4851.
 - Typical Actuators which require CP-8301-120 purchased separately: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-454.
 - Typical Actuators with CP-8301-120 factory installed and wired: MP-461-600, MP-471-600, MP-481-600, MP-2110-601.
 - Typical Actuators which require CP-8301-024 purchased separately: MP-361, MP-371, MP-381, MP-382, MP-2113-500.
 - Typical Actuators which require CP-8301-120 purchased separately: MP-465, MP-475, MP-483, MP-485, MP-486, MP495, MP-2130-500, MP-2150-500.
 - Typical Actuators which require CP-8301-240 purchased separately: MP5-2151-500, MP5-4651, MP5-4751, MP-4851, MP5-4851.
 - Typical Actuators which require CP-8391-913 purchased separately: MP-361, MP-371, MP-381, MP-382, MP-2113-500.
 - Typical Actuators which require CP-8391-910 purchased separately: MP-421, MP-422, MP-424, MP-451, MP-452, MP-453, MP-454.
 - Typical Actuators which require CP-8391-910 purchased separately: MP-465, MP-475, MP483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500.
 - Typical Actuators which require CP-8391-716 purchased separately: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-453, MP-454.
 - Typical 120 Vac Actuators which require CP-8391-716 purchased separately: MP-465, MP-475. MP-483, MP-485, MP-486, MP-495, MP-2130-500, MP-2150-500.
 - Typical 240 Vac Actuators which require CP-8391-716 purchased separately: MP5-2151-500, MP5-4651, MP5-4751, MP-4851, MP5-4851.
 - Typical Actuators: MP-361, MP-371, MP-381, and MP-382.
 - Typical Actuators: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, MP-453, MP-454, MP-461-600, MP-471-600, and MP-481-600.
 - Typical Actuators: MP-465, MP-475, MP-483, MP-486, MP-495, MP5-4651, MP5-4751, MP-4851, and MP5-4851.
 - Typical Actuator: MP-2113-500.
 - Typical Actuator: MP-2110-600.
 - Typical Actuators: MP-2130-500, MP-2150-500, MP5-2151-500.
 - Typical Actuators: MP-379 and MP-389
 - Typical Actuators: MP-470, MP-480, and MP-4701.
 - Typical Actuators: MP-367, MP-377, and MP-387.
 
 
 - List of Figures
 - INSTALLATION
 - MOUNTING
 - WIRING
 - ADJUSTMENTS
 - CHECKOUT
- GO, NO GO Test
- Slidewire Controller with 24 Vac Actuators
 - Slidewire Controller with Line Voltage Actuator
 - CP-8301-120, Vdc Interface (Schneider Electric System 8000) with Line Voltage Actuators without Internal Transformer
 - CP-8301-024, Vdc Interface (Schneider Electric System 8000) with 24 Vac Actuators
 - CP-8301-120 and CP-8301-240, Vdc Interface (Schneider Electric System 8000) with Line Voltage Actuators with Internal Transformer
 - CP-8391-xxx Series mAdc Interface
 
 - Positioning the Actuator with the Controller
 
 - GO, NO GO Test
 - REPLACEMENT PARTS
 - MAINTENANCE
 - TROUBLESHOOTING
 - REPAIR
 - DIMENSIONAL DATA
 
F-15479-10 © Copyright 2010 Schneider Electric All Rights Reserved. 25
Typical Actuators: MP-421, MP-422, MP-423, MP-424, MP-451, MP-452, 
MP-453, MP-454, MP-461-600, MP-471-600, and MP-481-600.
Figure-25  Internal Wiring for Line Voltage Actuators.
Typical Actuators: MP-465, MP-475, MP-483, MP-486, MP-495, MP5-4651, 
MP5-4751, MP-4851, and MP5-4851.
Figure-26  Internal Wiring for Line Voltage Actuator with Built-in Transformer.
L1
8
7
6
5
4
3
2
1
X
L2
M
o
t
o
r
CW CCW
CWCCW
Shading
Coils
100 
Ω
Internal
Potentiometer
CCW
CW
Limit Switches
Auxiliary
Switch
Case
Screw
Green
Wire
Green Case
Ground Screw
Field Coil
2
1
1 Used for field grounding.
2 External green jumper from 
terminal X to case ground is only 
available on current 
MP-xxx-xxx-x-2 models.
L1
8
7
6
5
4
3
2
1
X
L2
M
o
t
o
r
CW CCW
CWCCW
Shading
Coils
100
 Ω
Internal
Potentiometer
CCW
CW
Limit Switches
Auxiliary
Switch
Case
Screw
Green
Wire
Internal
Transformer
0 Vac
Blue
12 Vac
24 Vac
Red
Field
Coil
Green Case
Ground Screw
2
1
1 Used for field grounding.
2 External green jumper from terminal x to case ground is only 
available on current MP-xxx-xxx-x-2 models.
3 On models prior to current MP-xxx-xxx-2-x the Red and Blue 
transformer leads were wired directly to potentiometer.
3
3