Operating instructions
e
STATION
-
Initial parameter set up
BC8DX will be operated with the default values of the initial settings which were done at the factory, when
it is connected to a 12V DC battery or any similar input power source for the first time. The user can set
these values at his/her own requirements. These setup data will be commonly applied to both output
channels.
Select using ‘UP/DOWN’ or ‘INC/DEC’ buttons, and press ‘START/ENTER’.
PROGRAM SELECT
CH2>
LiPo
LiFe
LiIo
NiMH
NiCd
Pb
SETUP
REVIEW
[ USER SETUP ]
▶
▶
In vol. low : 10.0V
Temp mode : C
Key beep : On
Melody/Full : 1
LCD light : On
!
[ USER SETUP ]
▶
▶
LCD contrast : 0
Factory set : Reset
Password : ****
Name(17char)
ABCDEFGH123456789
START
ENTER
START
ENTER
SETUP
To manipulate the cursor, you can use ‘UP/DOWN’ or ‘INC/DEC’ buttons at ‘PROGRAM
SELECT’ screen. And you can use ‘UP/DOWN’ button to move the cursor in vertical direction
and use ‘INC/DEC’ buttons in horizontal direction. By pressing ‘STOP/ESC’ button, the screen
goes to previous menu at any time.
!
- 8 -
The first display
e-STATION
BC8DX V1.0
BALANCER Search... OK
BANTAM BC8DX
!
!
When you connect the crocodile clips which attached to the
charger as an input power cable to a suitable 12V power
source, the start-up display appears. The charger will carry
out self-test on balancer circuit instantly, and will show ‘OK’
on success at right bottom corner. Thus the power-on process
has been completed. If it fails to test the balancer circuit,
balance function for Lixx batteries can not work, but other
programs are fine to work. Even the case, the charger needs
to be repaired. The display shows the brand name, device name and firmware version as well as the
user’s name. The default display for user’s name is ‘BANTAM BC8DX’, but you can revise it by your
name at ‘SETUP’ program.
Press ‘START/ENTER’ button to go for the main menu display.
!