Operating instructions

e
STATION
-
!
Chg curr : 5.0A
Chg mode : Normal
Curr mode : Manual
Delta-peak : 10mV/C
Max capa : 100%
NiMH[ 1 ] 7S(8.4V)
3000mAh CHARGE
- Curr. mode (Current mode) : Set the charge current mode.
Manual; The charger will feed the charge current set at ‘Chg.
curr.’ for whole process.
Auto; The optimum charge current will be set by the charger
automatically. The charge current set at ‘Chg. curr.’ will be upper
limit of charge current.
- Delta-peak (Delta-peak voltage sensitivity) : Set the
Delta-peak voltage sensitivity at termination. (Disable, Delicate,
Default, 5~20mV/cell)
Disable; The charger would not detect Delta-peak voltage for
termination. To terminate charging process, the charger will check
the parameters set up at other safety parameters like max.
capacity, safety timer or safety temperature. If any one has been
reached at its limit, the charging process will be terminated. (for
NiMH only)
Delicate; The charger will detect a very small variation at
delta-peak voltage. Some NiMH batteries which shows small
voltage-drop at peak need to be use this option.
Default; If you do not know much about this function, or for
ordinary batteries, select this mode. 15mV/cell for NiCd or
10mV/cell for NiMH will be used.
- Tickle curr. (Trickle charge current) : Activate or deactivate the
trickle charge after the termination of process. (Off, 50 ~ 300mA)
- Peak delay : This restrains the delta-peak voltage detection until
the time is reached after starting the process. This prevents a
premature cut-off from the battery of high internal resistance. The
default value is one minute. (1 ~ 15 minutes)
Chg curr : 5.0A
Chg mode : Normal
Curr mode : Manual
Delta-peak : 10mV/C
Max capa : 100%
NiMH[ 1 ] 7S(8.4V)
3000mAh CHARGE
NiMH[ 1 ] 7S(8.4V)
3000mAh CHARGE
Delta-peak : 10mV/C
Max capa : 100%
Safety timer : 720min
Safety temp : 50C
Trickle curr : 100mA
NiMH[ 1 ] 7S(8.4V)
3000mAh CHARGE
Max capa : 100%
Safety timer : 720min
Safety temp : 50C
Trickle curr : 100mA
Peak delay : 5min.
!
- 15 -
!
!
!