Operating instructions

e
STATION
-
NiMH/NiCd battery program
Charging NiCd/NiMH battery
!
These programs are for charging or discharging NiMH
(Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium) battery
commonly used for R/C model applications. The charge
current varies according to the battery capacity and
performance. The type of battery which is either NiMH or
NiCd must be correct for the battery being charged.
Select the output channel that the program will be performed
by pressing ‘CHANNEL button, and select ‘NiCd’ or ‘NiMH’
which suits the type of battery being processed using UP/DOWN’ button. Press ‘START/ENTER’ button
to enter the program.
PROGRAM SELECT
CH2>
LiPo
LiFe
LiIo
NiMH
NiCd
Pb
SETUP
REVIEW
Chg curr : 5.0A
Chg mode : Normal
Curr mode : Manual
Delta-peak : 10mV/C
Max capa : 100%
NiMH[ 1 ] 7S(8.4V)
3000mAh CHARGE
You can choose a sub-program to be performed by pressing
‘MODE’ button, there are ‘CHARGE’, ‘DISCHARGE’ and
‘CYCLE’ programs. And then select the data number which will
newly set up, or load the data number already set up for re-use
using ‘INC’ or ‘DEC’ buttons. If you have the set-up data which
had been performed successfully before, you can just start the
process. All setup data will be stored at charger’s memory
automatically. Input the cell-count and capacity of the battery will
be charged. The cell-count and capacity need to be matched
with the battery. Use ‘UP/DOWN’ buttons to scroll up and down
the menu, and change the value using ‘INC/DEC’ buttons when
the pertinent field is blinking.
To start the process, press and hold ‘START/ENTER’ button for
more than 3 seconds.
- Chg. curr. (Charge current) : Set the charge current. (0.1 ~
9.0A)
- Chg. mode (Charge mode) : Set the charge mode which the
charger will work with.
Normal; The charger will work with the parameters which were
set at the screen. The feeding current will be zero at every 90
seconds to have 6 seconds of waste-time for higher charging
efficiency.
Linear; The charging current will be fed continuously without
hesitating. The battery is charged with pure ‘Direct-Current’.
Reflex; The battery will be charged using the pulsed current
which is very brief and high-rate discharge pulses. This will help
to prevent from undesired side effect like ‘memory effect’. When
you select this mode, you need to set the partial capacity percent
which will be charged with pulsed current. After set the percent
using ‘INC’ or ’DEC’ buttons, press ‘ESC’ to exit. The charger will
work with ‘Reflex’ mode only until the capacity has been charged
to the percent. After that, the charger will work at ‘Normal mode’
Chg curr : 5.0A
Chg mode : Normal
Curr mode : Manual
Delta-peak : 10mV/C
Max capa : 100%
NiMH[ 1 ] 7S(8.4V)
3000mAh CHARGE
Chg curr : 5.0A
Chg mode : Normal
Curr mode : Manual
Delta-peak : 10mV/C
Max capa : 100%
NiMH[ 1 ] 7S(8.4V)
3000mAh CHARGE
!
- 14 -
!
!
!