This is for Lithium battery not to be used for long time. The program will determine to charge or discharge
the battery to a certain voltage depending on the voltage of the battery at its initial stage. The final voltage
are different from type of batteries, 3.75V for LiIo, 3.85V for LiPo and 3.3V for LiFe per cell. If the voltage
of battery at its initial stage is over the voltage level to storage, the program will start to discharge.
'STORAGE' program for Lithium battery
- Chg. curr. (Charge current) : Set the charge current. (0.1 ~ 9.0A)
- Dchg. curr. (Discharge current) : Set the discharge current for the case of discharging. (0.1 ~ 5.0A)
- End curr. (End current) : Set the final charging current at termination. (Auto, 60~500mA)
Chg curr : 5.0A
Dchg curr : 3.0A
End curr : Auto
Max capa : 100%
Safety time : 720min
LiPo[ 1 ] 6S(22.2V)
3000mAh STORAGE
▶
LiPo[ 1 ] 6S(22.2V)
3000mAh STORAGE
▶
Dchg curr : 3.0A
End curr : Auto
Max capa : 100%
Safety time : 720min
Safety temp : 50C
Discharging Lithium battery
- Dchg. curr. (Discharge current) : Set the discharge current. The value may not exceed 1C for a
maximum safety. and (0.1 ~ 5.0A)
- Dchg. volt (Discharge volt) : Set the final voltage per cell. The final voltage should not be under the
voltage level that is recommended by the battery manufacturer to avoid deep discharging. The default is
2.70V/cell. (2.70~3.70V/cell)
- Dchg. mode (Discharge mode) : Set the discharge mode.
Normal; The charger will keep on discharging with the discharge current continuously until the discharge
voltage has been reached.
CV mode; The discharging current will start to be decreased gradually until the end current which will
be set up at next has been reached, when the voltage has been dropped to the final discharge voltage.
For maximum discharge, use this mode.
- End curr. (End current) : Set the final discharging current at termination. The end current should be
less than the initial discharge current.
Auto; The process will be terminated when the discharge current go to 1/10 of its initial value.
Otherwise, the discharge current will be decreased until the designated value has been reached. (Auto,
60~500mA)
Dchg curr : 5.0A
Dchg volt : 2.70V/C
Dchg mode : Normal
End curr : Not use
Max capa : 100%
LiPo[ 1 ] 6S(22.2V)
3000mAh DISCHARGE
▶
LiPo[ 1 ] 6S(22.2V)
3000mAh DISCHARGE
▶
Dchg mode : Normal
End curr : Not use
Max capa : 100%
Safety time : 720min
Safety temp : 50C
!