Operating Instructions e - STATION BC8DX Two identical and independent outputs with integrated balancer Charge current up to 9A, discharge current up to 5A, 1 to 8 series of LiIo/LiPo/LiFe, 1 to 22 cells of NiCd/NiMH, 2 to 28V of Lead-acid (Pb) at each output * We reserve the right to commit modifications.
Special features - Operating software The operating program in this charger is executed with mutual links and communications with every components to prevent any possible error, so it introduces the maximum safety. Especially, the charging algorithm is so multifarious that you can select the best program to suit your requirement. And BC8DX has a large LCD for showing various informations including charge/discharge graphs during the process.
Exterior of the charger Intelligent cooling fan Input (12V DC) Power cable CHANNEL Graphic LCD buttons 128 X 64 dot matrix STOP/ESC buttons Intelligent cooling fan USB port ▶ OUTPUT-1 Temperature MODE UP/DOWN DEC/INC port buttons buttons buttons Individual cell port Temperature port OUTPUT-2 START/ENTER Individual cell buttons port - ‘CHANNEL’ button Switches the screen display between output-1 and output-2.
Warnings and safety notes Never leave the charge unsupervised when it is connected to its power supply. If any malfunction is observed, terminate the process immediately and refer to the operating instructions. Keep away the unit from dust, damp, rain, heat direct sunshine and vibration. Do not drop it. The circuit of the unit is designed to be powered by a 12V DC like car battery or similar DC power supply.
Please bear in mind of checking the following point before charge operation. - Did you select the appropriate program, which are suitable for the type of battery? - Did you set up adequate current for charging or discharging? - Lithium battery pack can be composed with parallel and series circuits mixed. You have to check the composition of the battery pack carefully before charging.
Program flow chart LiPo/LiFe/LiIo PROGRAM UP ENTER Charge current 0.1~9.0A CHARGE DOWN UP Charge mode Normal/Balance/Fast DOWN UP DOWN End current Auto, 60~500mA UP UP Safety temp. 20~80C MODE UP DOWN DOWN Maximum capacity 50~120% DOWN Charge current 0.1~9.0A STORAGE UP Safety timer 10~9990 min. UP Discharge current 0.1~5.0A DOWN UP DOWN UP DOWN Check Time 5~250 min. End current Auto, 60~500mA UP UP Safety temp. 20~80C MODE UP UP Discharge current 0.1~5.
Pb(Lead-acid) PROGRAM UP Charge current 0.1~9.0A CHARGE DOWN UP Charge volt 2.20~2.50V/cell DOWN UP Charge mode Liner/Pulse DOWN UP Safety temp. 20~80C MODE UP UP UP Safety timer 10~9990 min. DOWN DOWN UP Maximum Capacity 50~150% DOWN End current Auto/60~500mA DOWN DOWN Trickle curr. Off/50~300mA UP Discharge current 0.1~5.0A DISCHARGE DOWN UP Discharge volt 1.40~1.80V/cell DOWN UP Discharge mode Normal/CV mode DOWN UP Safety temp.
The first display When you connect the crocodile clips which attached to the charger as an input power cable to a suitable 12V power source, the start-up display appears. The charger will carry BC8DX V1.0 out self-test on balancer circuit instantly, and will show ‘OK’ on success at right bottom corner. Thus the power-on process B A N TA M B C 8 D X has been completed. If it fails to test the balancer circuit, BALANCER Search...
- Temp. Mode : Choice of temperature mode. (C, Celcius or F, Fahrenheit) ▶ - In Vol. Low : This program monitors the voltage of input battery. If the voltage drops below the value you set the operation forcibly terminated to protect the input battery. (10.0 ~ 11.0V) - Key Beep : The beep sounds at every time pressing the buttons to confirm your action. - LCD Light : LCD back-light can be on and off.
Lithium battery (LiIo/LiPo/LiFe) program These programs are only suitable for charging and discharging Lithium batteries with a nominal voltage of 3.3V, 3.6V or 3.7V per cell. These batteries need to adopt different charge technique is NiCd LiPo termed constant voltage(CV) and constant current (CC) method. LiFe Pb The charge current varies according to the battery capacity and LiIo SETUP performance.
LiPo[ 1 ] 3000mAh 6S(22.2V) ▶ CHARGE Chg Chg End Chk Max : : : : : curr mode curr time capa 5.0A Normal Auto 10min 100% LiPo[ 1 ] 3000mAh 6S(22.2V) ▶ CHARGE Chg Chg End Chk Max : : : : : curr mode curr time capa 5.0A Normal Auto 10min 100% LiPo[ 1 ] 3000mAh 6S(22.2V) ▶ CHARGE Chg Chg End Chk Max : : : : : curr mode curr time capa 5.0A Normal Auto 10min 100% - Chg. mode (Charge mode) : You can select a method of charging, they are Normal, Balance, FAST.
'STORAGE' program for Lithium battery This is for Lithium battery not to be used for long time. The program will determine to charge or discharge the battery to a certain voltage depending on the voltage of the battery at its initial stage. The final voltage are different from type of batteries, 3.75V for LiIo, 3.85V for LiPo and 3.3V for LiFe per cell. If the voltage of battery at its initial stage is over the voltage level to storage, the program will start to discharge.
Safety programs for all types of battery - Max. capa. (Maximum capacity) : You can define the maximum capacity which can be charged or discharged by the form of a percentage of battery capacity set in the top of display. If full-charge has not been detected for any reason, the charger limits the quantity of feeding energy by the value and terminates the process as on the value is reached.
NiMH/NiCd battery program These programs are for charging or discharging NiMH (Nickel-Metal-Hydride) or NiCd (Nickel-Cadmium) battery commonly used for R/C model applications. The charge NiCd LiPo current varies according to the battery capacity and LiFe Pb performance. The type of battery which is either NiMH or LiIo SETUP NiCd must be correct for the battery being charged.
NiMH[ 1 ] 3000mAh Chg curr Chg mode Curr mode Delta-peak Max capa NiMH[ 1 ] 3000mAh Chg curr Chg mode Curr mode Delta-peak Max capa NiMH[ 1 ] 3000mAh Delta-peak Max capa Safety timer Safety temp Tr i c k l e c u r r NiMH[ 1 ] 3000mAh Max capa Safety timer Safety temp Tr i c k l e c u r r Peak delay ▶ 7S(8.4V) CHARGE : : : : : 5.0A Normal Manual 10mV/C 100% 7S(8.4V) ▶ CHARGE : : : : : 5.0A Normal Manual 10mV/C 100% 7S(8.
Discharging NiCd/NiMH battery NiMH[ 1 ] 3000mAh Dchg curr Dchg mode Dchg volt Max capa Safety timer ▶ 7S(8.4V) DISCHARGE : : : : : 5.0A Normal Default 100% 720min NiMH[ 1 ] 3000mAh Dchg mode Dchg volt Max capa Safety timer Safety temp ▶ 7S(8.4V) DISCHARGE : Normal : Default : 100% : 720min : 50C - Dchg. curr. (Discharge current) : Set the discharge current. (0.1 ~ 5.0A) - Dchg. mode (Discharge mode) : Set the discharge mode which the charger will work with.
Pb (lead-sulphuric acid) battery program This is programmed for charging Pb (lead-acid) battery with nominal voltage from 2 to 28V. Pb batteries are totally NiCd LiPo different from NiCd or NiMH batteries, but very similar with LiFe Pb Lithium batteries. They can only deliver relatively lower current compare to their capacity, and similar restrictions definitely LiIo SETUP apply to charge. So the optimal charge current will be 1/10 of NiMH REVIEW the capacity. Pb batteries must not be charged rapidly.
Pb[ 1 ] 12000mAh Chg Chg Chg End Max curr volt mode curr capa Pb[ 1 ] 12000mAh End curr Max capa Safety timer Safety temp Tr i c k l e c u r r 6S(12.0V) ▶ CHARGE : : : : : 5.0A Default Linear Auto 100% 6S(12.0V) ▶ CHARGE : Auto : 100% : 720min : 50C : 100mA - End curr. (End current) : Set the final charging current at termination. Auto; The process will be terminated when the charging current go to 1/10 of its initial value.
Screen displays during process As the program starts by pressing ‘START/ENTER’ button, the LCD will be changed to show the charge or discharge graph, and also some other data. Those displays can be altered by pressing ‘INC’ or ‘DEC’ button. The display will go back to the graph screen automatically, after showing the data screen in three minutes. 2 1 6 5 4 3 7 CHG ▶ 0039:15 NiMH 00298mAh 13.07V 1.25A 8 INC/DEC BAL ▶ 0039:15 LiPo 00298mAh 12.43V 1.25A C1: C2: C3: C4: 4.12V 4.12V 4.13V 0.
Review the data after finishing the process PROGRAM SELECT CH2> NiCd Pb SETUP REVIEW LiPo LiFe LiIo NiMH DAT GRP Input vol Output vol Ext. temp Chg time Dchg time Capacity CYE : : : : : : CEL ▶ 12.35V 10.54V 42C 52min 0min 898mAh UP/DOWN 4 2 1 After finishing the program, you can review the data which had been pertained to the input and output of the charger by selecting R E V I E W menu at the main screen. These data can not be shown while the program is being on process.
Warning and error messages BC8DX incorporates a various functions of protective and monitoring the system to verify functions and the state of its electronics. In any case of occurring error, the screen displays the cause of error that is self-explanatory with audible sound. Check connection ... Reversed polarity The output is connected to a battery with incorrect polarity. STOP/ESC Check charger ... Over-temperature The internal temperature of the unit goes too high. Cool down the unit.
Glossary of terms Amps(A): The unit of measure for charge or discharge electric current. The program of the charger will show most of the current in amps(A) at its LCD screen. Milliampere(mA): The electric current, being amps(A) multiplied by 1000 and noted as 'mA'. So 2.0A is the same as 2000mA (2.0x1000). Or, to convert mA to amps, divide the mA number by 1000. So 200mA is the same as 0.2A. If a current value is below 1.
Maximum circuit power chart For the voltage of battery is more than 16V, the actual amount of charge current feeds to the battery might automatically be limited, so not to exceed the charger's maximum rated charging power of 160 watts at an output channel. And also, for the battery having more than 5V, the discharge current delivered to the battery might be limited by the maximum rated discharge power of 25 watts per output. Maximum charge/discharge current at 12V DC input NiCd/NiMH LiPo LiFe Pb No.
Specifications Operating voltage range : Circuit power : Charge current : Discharge current : NiCd/NiMH battery cell count : Lithium battery cell count : Pb battery voltage : Battery data memory : Battery capacity range : Delta-peak sensitivity : Temperature cut-off range : Trickle charge current : Cycle count : Cycle cool-off waste time : Current drain for balancing Lixx : Weight : Dimensions : 10.0 ~ 18.0V DC 12V Lead-acid battery or equivalent high power PSU Charge max. 160W per output Discharge max.