It’s extremely important to check the carbon brush periodically. It must be replaced when the
remaining length is less than 7.5mm.
To replace, insert the carbon brush into the carbon holder and put the brush cap into the hole. Before
tightening the carbon brush holder, make sure to position the O-ring. There are two carbon brushes
on opposite sides of hoist body. They both need to be replaced at the same time (see figure).
Maintenance
Always turn off the push button switch immediately after use. To avoid potential danger, always make
sure you are looking up toward the hoist when operating it. Prior to using, always inspect the hoist for
any damages or wear.
Oil Lubrication
The hoist is prefabricated at the factory and does not require initial lubrication. Recommended oil
replenishment quantities and intervals are as follows.
Grease Grade
Quantity
Intervals
Caltex Multifak Ep
300 cc
1 Year
Cosmogear SE220