User guide

Teaching Limits Using the Auto-Window Feature
Teaching the same limit twice automatically centers a 20 mm window on the
taught position.
General Notes on Programming
The sensor returns to Run mode if the first TEACH condition is not regis-
tered within 120 seconds.
After the first limit is taught, the sensor remains in Program mode until the
TEACH sequence is finished.
To exit Program mode without saving any changes, press and hold the pro-
gramming push button for more than 2 seconds (before teaching the sec-
ond limit). The sensor reverts to the last saved program.
Figure 4. Using the Auto-Window feature for pro-
gramming each output
Procedure
Result
Push Button (0.04 sec ≤ Click ≤ 0.8
sec)
Remote Line (0.04 sec < T < 0.8 sec)
Programming
Mode
Press and hold push button No action required; sensor is ready for 1st
limit teach
Output LED: ON Red
Power LED: ON Green (good signal) or ON
Red (no signal)
Teach First
Limit
Position the target for the first limit Position the target for the center of the
window
Power LED: Must be ON Green
"Click" the push button Single-pulse the remote line
T
Teach Accepted
Output LED: Flashing Red
Teach Unacceptable
Output LED: ON Red
Re-Teach
Limit
Without moving the target, "click" the
push button again
Without moving the target, single-pulse
the remote line again
T
Teach Accepted
Output LED: Yellow or OFF
Teach Unacceptable
Output LED: Flashing Red
Output OFF Output ON
Taught Position
(background surface)
Near
Range
Position
-10 mm
Position
+10 mm
Sensor
Output
ON
Sensor
Output
OFF
Any object in this area will switch
the output, whether or not the object
returns a good signal to the sensor.
Sensing Distance
Figure 5. An application for the Auto-Window feature (retroflective mode)
WORLD-BEAM QS18U Ultrasonic Sensors
P/N 119287 Rev. H www.bannerengineering.com - tel: 763-544-3164 5