Owner's manual

Hookups
NPN (Sinking) Output Selected
3
1
4
2
12-30V dc
Remote
Programming
(N.O.)
+
Load
Shield*
* It is recommended that the shield wire be connected to
either earth ground or DC common.
PNP (Sourcing) Output Selected
Shield*
* It is recommended that the shield wire be connected to
either earth ground or DC common.
3
1
4
2
12-30V dc
+
Remote
Programming
(N.O.)
Load
Wiring Key
1 = Brown
2 = White
3 = Blue
4 = Black
Cable and QD hookups are functionally identical.
Shielded cordsets are recommended for all QD models.
Dimensions
ø 15
[0.6"]
51.1
[2.01"]
63.6
[2.50"]
Ø40.2
[1.58"]
23.4
[0.92"]
M30 x 1.5
Max. Torque 2.3 Nm (20 in-lbs.)
22.5
[0.89"]
45.0
[1.77"]
M12 x 1
Locknut (included with all models)
M30 x 1.5
3x 36.1
[1.42"]
10
[0.4"]
5
[0.2"]
Ø39.6
[1.56"]
Washer (included with all models)
Ø40
[1.6"]
1.6
[0.06"]
Ø30
[1.2"]
U-GAGE® T30UX Series with Discrete Output
10 www.bannerengineering.com - tel: 763-544-3164 P/N 138381_web
Rev. G