Owner's manual

Ultrasonic Sensor with TEACH-Mode Configuration
1, 2 and 3 m (3.28, 6.56, and 9.84 ft) versions with short dead zones (10% of
max range)
Built-in temperature compensation
Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments
Remote TEACH for security and convenience
Wide operating temperature range of −40° to +70° C (−40° to +158° F)
Outputs can be set for either NPN (sinking) or PNP (sourcing), Normally Open
(N.O.) or Normally Closed (N.C.)
Compact, self-contained, right-angle sensor package with fully encapsulated
electronics
ULTRASONIC
Models
Models Range and Frequency Cable
1
Supply Voltage Discrete Output Response Time
T30UXDA
100 mm to 1 m (3.9 in to 39 in)
224 kHz
Standard 2 m
(6.5 ft) cable
10 to 30V dc
NPN, PNP, NO,
NC, Selectable
45 ms
T30UXDB
200 mm to 2 m (7.8 in to 78 in)
174 kHz
92 ms
T30UXDC
300 mm to 3 m (11.8 in to 118 in)
114 kHz
135 ms
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
1
Only standard 2 m (6.5 ft) cable models are listed. For 4-Pin Euro-Style integral QD, add suffix “Q8” to the model number (for example, T30UXDAQ8). For 150 mm (6 in) PUR pigtail
cable with 4-Pin threaded Euro-Style QD, add suffix “QPMA” to the model number (for example, T30UXDAQPMA). For 9 m (30 ft) cable, add suffix “W/30” to the model number (for
example, T30UXDA W/30). A model with a QD connector requires a mating cable; see Quick-Disconnect Cables on page 11.
U-GAGE® T30UX Series with Discrete Output
P/N 138381_web
Rev. G
8/19/2013

Summary of content (12 pages)