Owner manual

Program Second Output
Repeat as needed for other output.
Teaching Identical (Complementary) Window Limits for Both Outputs
Figure 4. Programming one pair of sensing window limits, com-
plementary outputs
Only one output conducts at any time in response to the target distance. Under no conditions will
both outputs conduct at the same time; see Overview on page 1 and the figure on the left.
The distance between the taught near and far limits must be at least 10 mm in this complementa-
ry mode for proper sensor operation.
Push Button
Remote Wire
0.04 sec. < T < 0.8 sec.
Procedure Result Procedure Result
Programming Mode
Press and hold both push but-
tons (or press and hold one and
then the other)
3
>2 sec.
Green Power LED turns OFF
Both Output LEDs turn ON Yellow
Sensor waits for first limit
No action required
Teach First Limit
Position the target for the first
limit
“Click” either push button
After a short delay, the Yellow
LEDs flashes
Sensor learns first limit and waits
for second limit
Position the target for the first limit
Triple-pulse the remote line
T T T T T
Green Power LED turns OFF
Both Output LEDs turn ON Yellow
After a short delay, the Yellow LEDs
flash
Teach Second Limit
Position the target for the sec-
ond limit
“Click” either push button
After a short delay, the Green
Power LED goes ON
Sensor learns second limit and re-
turns automatically to Run mode
Position the target for the second limit
Single-pulse the remote line
T
After a short delay, the Green Power
LED turns ON
Sensor learns second limit and re-
turns automatically to Run mode
3
Sensor will return to RUN mode if first TEACH condition is not registered within 120 seconds.
U-GAGE® T30U Series Sensors - Pump-In/Pump-Out