Push Button Lockout
Enables or disables the push button to prevent unauthorized adjustment of the program
settings.
Procedure
Result
Push Button
Remote Wire
0.04 sec. < T < 0.8 sec.
Enable/Disable
Push Button
• Not available via push button • Four-pulse the remote line
Push buttons are either enabled or disabled,
depending on previous condition.
T
T
T
T
T
T T
T T T
T T
T T
T
T T
T T
T
Procedure
Result
Push Button
Remote Wire
0.04 sec. < T < 0.8 sec.
Toggle between
N.O. / N.C. Operation
• Not available via push button • Triple-pulse the remote line
Either Normally Open or Normally Closed
operation is selected, depending on previous
condition.
T
T
T
T
T
T T
T T T
T T
T T
T
T T
T T
T
Normally Open/Normally Closed Operation Select
The sensor can be configured for either normally open or normally closed operation
via the remote teach wire (gray). A series of three pulses on the line will toggle
between normally open and normally closed operation. Normally open is defined as the
output energizing when the target is present. Normally closed is defined as the output
energizing when the target is absent. See Figures 3 and 4.