User guide

Printed in USA 02/05 P/N 108964 rev. A
U-GAGE
S18U Series Sensors with Discrete Output
18 mm Ultrasonic Sensors with TEACH-Mode programming
Features
Fast, easy-to-use TEACH-Mode programming; no potentiometer adjustments
Short dead zone
One NPN and one PNP output
Two bi-colored status LEDs
Rugged encapsulated design for harsh environments
Choose 2 meter or 9 meter unterminated cable, or 5-pin Euro-style QD connector
Wide operating range of -20° to +60°C (-13° to +140°F)
Choose either straight or right-angle housing
Temperature compensation
Configurable for normally open or normally closed operation
Fast response time (5 milliseconds)
Model
Number
Sensing
Range
Cable*
Supply
Voltage
Output
Housing
Configuration
S18UBA
30 to 300 mm
(1.2" to 11.8")
5-wire, 2 m (6.5') cable
10 to 30V dc
Bipolar
NPN/PNP
Straight
S18UBAQ
5-pin Euro-style QD
S18UBAR
5-wire, 2 m (6.5') cable
Right-Angle
S18UBARQ
5-pin Euro-style QD
Models
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.
!
* 9 m cables are available by adding suffix “W/30” to the model number of any cabled sensor (e.g., S18UBA W/30).
A model with a QD connector requires a mating cable; see page 10.
Straight Housing
Right-Angle Housing
Information about analog-output models is available on Banner’s website: www.bannerengineering.com
Ultrasonic Proximity Mode