Manual

P/N 110738 rev. A 5
U-GAGE
S18U Series Sensor Analog Output
Banner Engineering Corp. Minneapolis, MN U.S.A.
www.bannerengineering.com • Tel: 763.544.3164
Procedure
Result
Push Button
0.04 < “click” < 0.8 sec.
Remote Wire
0.04 sec. < T < 0.8 sec.
Programming
Mode
Push and hold the
push button
No action required; sensor is ready for
first limit teach
Output LED: ON Red
Power LED: ON Green (good signal) or
ON Red (no signal)
Teach Limit
Position the target for
the center of the window
Position the target for the center of the
window
Power LED: Must be ON Green
“Click” the push button • Single-pulse the remote line
Teach Accepted
Output LED: Flashing Red
Teach Unacceptable
Output LED: ON Red
Re-Teach
Limit
Without moving the
target, “click” the
push button again
Without moving the target,
single-pulse the remote line
again
Teach Accepted
Output LED: Yellow or OFF
Teach Unacceptable
Output LED: Flashing Red
T
T
T
T
T
T T
T T T
T T
T T
T
T T
T T
T
T
T
T
T
T
T T
T T T
T T
T T
T
T T
T T
T
...
...
D
or
...
...
D
or
...
...
D
or
Teaching Limits Using the Auto-Window Feature
Teaching the same limit twice for the same output automatically centers a 100 mm
window on the taught position.
General Notes on Programming
The sensor will return to Run mode if the first Teach condition is not registered
within 120 seconds.
After the first limit is taught, the sensor will remain in Program mode until the Teach
sequence is finished.
To exit Program mode without saving any changes, press and hold the programming
push button > 2 seconds (before teaching the second limit). The sensor will revert to
the last saved limits.
Using this procedure the analog output will be centered on the taught position at
approximately 5V dc or 12 mA.