Manual

Wiring
Cabled Models QD Models
Normally Open/Pump-In Normally Open/Pump-In
Load
bk
ye
bn
bu
wh
85-264V ac, 50/60 Hz
48-250V dc**
shield*
Output Current
8A Max.
bk
ye
bn
bu
wh
shield*
Output Current
(4A or 8A Max.)***
Load
85-264V ac, 50/60 Hz
48-250V dc**
Normally Closed/Pump-In
Normally Closed/Pump-In
bk
ye
bn
bu
wh
shield*
Output Current
8A Max.
Load
85-264V ac, 50/60 Hz
48-250V dc**
bk
ye
bn
bu
wh
shield*
Load
Output Current
(4A or 8A Max.)***
85-264V ac, 50/60 Hz
48-250V dc**
* Banner recommends that the shield wire be connected to earth ground.
** DC wiring is without regard to polarity
*** 4 A max. for sensors with Micro-style QD; 8 A max. for sensors with Mini-style QD.
Accessories
5-Pin Mini-Style Cordsets with Shield
Model Length Style Dimensions Pinout (Female)
MBCC2-506 1.83 m (6 ft)
Straight
7/8-16UN-2B
ΓΈ 28 mm max.
(1.1")
61 mm max.
(2.4")
4
3
1
5
2
1 = Brown
2 = White
3 = Blue
4 = Black
5 = Yellow
MBCC2-515 4.57 m (15 ft)
MBCC2-530 9.14 m (30 ft)
U-GAGE QT50UVR Series Sensors
P/N 117764 Rev. F www.bannerengineering.com - tel: 763-544-3164 9