User guide
Limits
N
1 2 3 4 5
3
4
5
1
2
7
Resp.
Speed
+
–
6
Figure 1. Analog Q45U Features
1 - Push button for programming sensing window limits
2 - 5-segment target position indicator (N = near)
3 - Green POWER indicator LED
4 - Red SIGNAL indicator LED
5 - Amber OUTPUT indicator LED
6 - Response adjustment
7 - Slots for removing inner cover
Output Response Settings
Important: Remove power before making any internal adjustments.
Using the two slots shown in Figure 1 on page 2, a small flat-blade screwdriver may be used to lift up and remove the black inner cover to
expose the 4-position DIP switch. Use these DIP switches to program the output slope, output mode, loss of echo, and min./max. output
value default.
DIP Switch Function Settings
1 Output slope On = Output value increases with distance
Off* = Output value decreases with distance
1
ON
2 3 4
Figure 2. DIP Switches for Q45U Sensors
2 Output mode On = Current output enabled
Off* = Voltage output enabled
3 Loss of echo On = Min - Max Mode
Off* = Hold Mode
4 Min-Max On* = Default to maximum output value
Off = Default to minimum output value
* Factory default setting.
Q45U Ultrasonic Sensors with Analog Outputs (Short Range)
2 www.bannerengineering.com - tel: 763-544-3164 P/N 47818 Rev. E